82
Figure 149 Setting the percentage of available capacity
Clearing RAID array information on the drive
This task allows you to clear remaining RAID array information on the drive for reconfiguring RAID
array on the drive.
To clear RAID array information on the drive:
1.
Switch the drive state from
Unconfigured Bad
to
Unconfigured Good
. For more information,
see "
2.
On the
Foreign View
screen as shown in
, select the target storage controller and
press
F2
. Select
Foreign Config
>
Clear
and press
Enter
.
Figure 150 Selecting Foreign Config > Clear
3.
On the dialog box that appears as shown in
, select
OK
and press
Enter
.