Version
field might vary by server model.
Figure 21 Verifying VMD status
Configuring RAID arrays
Prerequisites
Make sure the number of NVMe drives meets the requirements for RAID configuration. Execute the
lsblk
command to view the number of NVMe drives, as shown in
Figure 22 Viewing the number of NVMe drives
Procedure
1.
Execute the
mdadm -C /dev/md/imsm0
/dev/nvme[1-4]n1 -n 4 -e imsm
command
to create a container, as shown in