30
Figure 49 Controller Settings screen
3.
On the screen as shown in
, you can view the basic configuration of the storage
controller. Select
RESET
, and press
Enter
.
IMPORTANT:
The backplane mode sets the LED lighting policy. After the storage controller configuration is
restored to the default, the LED lighting policy becomes IBPI, which causes the LED to operate
abnormally. You must set the LED lighting policy to SGPIO.
Figure 50 Controller Configuration screen
4.
On the screen as shown in
, select
PROCEED
or
SUBMIT
, and press
Enter
to
restore the storage controller configuration to the default.