6
Switching the drive state
The storage controller supports the following drive states:
•
Unconfigured Good
—The drive is normal and can be used for RAID array or hot backup
configuration.
•
Unconfigured Bad
—The drive is faulty or has RAID array information remaining on it. If the
drive is faulty, replace the drive. If RAID array information remains on the drive, clear the RAID
array information.
•
Hotspare
—The drive is a hot spare drive.
•
JBOD/JBOD online
—Just a Bunch Of Disks. The drive is a passthrough or passthrough-like
drive and does not support RAID configuration. The passthrough drive is in
JBOD online
state
by default for the RAID-LSI-9560-LP-16i-8GB storage controller and in
JBOD
state for other
storage controllers.
To switch from
Unconfigured Good
state to
Unconfigured Bad
state:
1.
On the storage controller configuration screen as shown in
, select
Drive
Management
and press
Enter
.
Figure 5 Storage controller configuration screen
2.
On the screen as shown in
, select the target drive and press
Enter
.
Summary of Contents for UniServer E3200 G3
Page 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Page 116: ...56 Figure 96 Controller Configuration screen...
Page 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Page 243: ...84 Figure 153 Confirming the operation...
Page 293: ...50 Figure 89 Clearing completion...
Page 382: ...21 Figure 27 Storage controller information...
Page 389: ...7 Figure 8 Identifying a storage controller 2...