6-10
Table 6-1 Supercapacitor extension cable selection
Storage
controller type
Storage controller model
Supercapacitor
Extension
cable P/N
Mezzanine
•
RAID-P430-M1
•
RAID-P430-M2
Supercapacitor of the
Flash-PMC-G2 power fail
safeguard module
N/A
The cable does
not have a P/N.
RAID-P460-M2 BAT-PMC-G3
0404A0TG
RAID-P460-M4 BAT-PMC-G3
0404A0TG
RAID-L460-M4 BAT-LSI-G3 0404A0XH
Standard
•
RAID-LSI-9361-8i(1G)-A1-X
•
RAID-LSI-9361-8i(2G)-1-X
Supercapacitor of the
Flash-LSI-G2 power fail
safeguard module
0404A0SV
•
RAID-LSI-9460-8i(2G)
•
RAID-LSI-9460-8i(4G)
BAT-LSI-G3 0404A0VC
RAID-P460-B2 BAT-PMC-G3
0404A0TG
RAID-P460-B4 BAT-PMC-G3
0404A0TG
Prerequisites
•
Identify the type of the storage controller based on the drive configuration. For more information,
see "Drive configurations and numbering."
•
If you are installing a power fail safeguard module, make sure it is compatible with the storage
controller. For information about storage controllers and their compatibility matrices, see
"Storage controllers."
Installing a Mezzanine storage controller and a power fail
safeguard module
Procedure
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Remove the power supply air baffles if it hinders storage controller installation. For more
information, see "
5.
Remove a riser card if it hinders storage controller installation. For more information, see
"
Replacing a riser card and a PCIe module
."
6.
Align the pin holes in the Mezzanine storage controller with the guide pins on the system board.
Insert the guide pins into the pin holes, and then fasten the three captive screws to secure the
controller onto the system board, as shown in
.
NOTE:
The installation method for all Mezzanine storage controllers is the same. This figure is for
illustration only.