98
Figure 112 Installing the chassis-open alarm module
3.
Connect the cable assembly for front I/O components and the chassis-open alarm module to
the system board.
4.
Install the fan cage. For more information, see "
5.
Install all fan modules. For more information, see "
6.
Install the chassis air baffle. For more information, see "
Installing the chassis air baffle
7.
Install the access panel. For more information, see "
8.
Rack-mount the server. For more information, see "
9.
Connect the power cord. For more information, see "
10.
Power on the server. For more information, see "
Replacing a fan module
Guidelines
The fan modules are hot swappable.
The server must be fully configured with same model fans.
If sufficient space is available for replacement, you can replace a fan module without removing the
server from the rack.
If you install a GPU, make sure the FAN-H-4UG5 high-performance fan modules are used.
Removing a fan module
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "