8.7.2 Operation via buttons in the lid of the control unit
Emergency
stop
Lifting / reeling the rope
Lowering / unreeling the rope
Warning light (red)
8.7.3 Operation via wall control unit
Emergency stop
Lowering / unreeling the rope
Lifting / reeling the rope
Warning light (red)
8.7.4 Operation via radio remote control
Start transmitter
– Release the emergency stop at the bottom end.
– Start the control by pressing the “Start” buttons at the same
time (see illustration).
Acknowledge errors
Press the “Acknowledge” button
Emergency stop
Lowering /
unreeling the rope
Lifting /
reeling the rope
“Start” buttons
“Acknowledge”
button
Transmitter
Receiver
8.8 coil heater
Motors that are used in humid environments and/or under
strong temperature fluctuations can be supplied with a heating
element to protect against condensation water.
The single-phase supply (which is located in the terminal box)
is provided via an additional terminal strip.
Power consumption:
construction size
1~230V+10%
P [W]
56 ... 80
10
90 ... 160
25
Modifications of the design and execution reserved.
never feed the coil heater during motor operation.
8.9 control, indirect, with Electrical load limiter
Corresponds in design and working method basically to the
control with pendant pushbutton, indirectly (Chapter 8.7)
The power consumption of the motor is additionally measured
by means of an active power meter during "lifting" operation. If
the current exceeds (overload) the set value (level), the motor
is switched off and the red lamp on the switchbox lights up.
If there is no "malfunction" according to Chapter 8.7, then
there is an overload shutdown. Then only a "lowering" move-
ment (unreeling the rope) is possible. Short lowering quits the
overload protection. "Lifting" is possible again after eliminating
the overload.
The active power meter has been adjusted in the factory.
– As a safety component, this must be regularly, however
at least once annually checked by the operator as well as
before commissioning.
Observe in this respect:
– Does the Ident-No. correspond(ID.-No.: 890060) to the spe-
cifications of the type plate of the active power meter?
– Only use devices with same ID No.!
S1 = UL;
S2 = U;
ts = 0,5 s;
tr = 0,3 s
S1 = UL
Error LED
S2 = U
Level
Range
ts = 0,5
tr = 0,3
Settings – parameters range and level:
Type
Power
supply
voltage.
ESF/
ESG
150
ESF/
ESG
250
ESF/
ESG
500
ESG
750
ESG
990
Range
230VAc
400VAc
--
1
4
2
8
2
7
3
--
3
level %
± 5 %
230VAc
400VAc
--
70 %
85 %
55 %
70 %
100 %
80 %
100 %
--
90 %
Type
Power
supply
voltage.
ESG
1100
ESG
1500
ESG
2100
Range
230VAc
400VAc
6
--
--
3
--
4
level %
± 5 %
230VAc
400VAc
90 %
--
--
85 %
--
90 %
Disconnection at 110% of the nominal load!