1
96-0041 Rev V
March 2012
1. WARRANTY
All new HAAS Toolroom Mills are warranted exclusively by the Haas
Automation’s (“Manufacturer”) limited warranty against defects in material and
workmanship for a period of one (1) year from the date of purchase, which is
the date that a machine is installed at the end user. See the Warranty section
of the Mill Operator’s Manual for further warranty information.
2. SAFETY
Read and Follow all safety warnings
- Familiarize yourself with the
Operator’s Manual Safety chapter. Be aware of the other people around you
in the shop; lying chips can seriously injure people, who may not be a safe
distance away. Always wear safety glasses. Initial cuts/setups should be cut at
a slower speed to reduce the possibility of tool or machine damage.
3. INSTALLATION
NOTE
: These installation recommendations are to be used in conjunction
with those in the Reference Manual. Material supplied here is
given speciically for the Toolroom Mill.
e
lecTriciTy
r
equiremenTs
IMPORTANT! REFER TO LOCAL CODE REQUIREMENTS BEFORE
WIRING MACHINES.
• The power source must be grounded
• Frequency range is 47-66 Hz
• Line voltage that does not luctuate more than +/-5%
• Voltage imbalance or no more than 2%
• Harmonic distortion is not to exceed 10% of the total RMS voltage
Voltage Requirements
Toolroom Mill
208 3PH / 240V 1PH ±10%
Power Supply
40 AMP
Haas Circuit Breaker
40 AMP
If service run from elec. panel
is less than 100’ use:
1PH - 8 GA WIRE/3PH - 10 GA WIRE
If service run from elec. panel
is more than 100’ use:
1PH - 6 GA WIRE/3PH - 8 GA WIRE
WARNING!
A separate earth ground wire of the same conductor size as input power is
required to be connected to the machine chassis. This ground wire is required
for operator safety and proper operation. This ground must be supplied from
the main plant ground at the service entrance, and should be routed in the
same conduit as input power to the machine. A local cold water pipe, or ground
rod adjacent to the machine cannot be used for this purpose.