1. General instructions

• When unpacking the appliance, please check whether it has not suffered harm during transport. Report

possible faults to your specialised vendor of stoves immediately!
Note: The return draft boards which are loose or which loosened from their embedding etc. do not constitute
defects (see Specification –First putting into service).

• During the installation, connection and putting in operation there must be observed national and European

standards, local and building regulations, as well as the Building Order of the respective country, or the
Decree of fire-boxes.

• The fireplace stove, described in this Manual, has been checked according to DIN EN13240. The door of

the combusting space must be closed during the heating always.

• The fireplace stove is a fire box for interrupted combustion, and is suitable for multiple employment of a

chimney. Please observe the international regulations.

2. Safety instructions

• With the stoves equipped with an intake of external air, the orifice must not be closed during operation of the

stove.

• During operation of the stove, the installed orifice for the intake of combustion air must not be closed,

partially closed, straitened, covered or blocked.

• During the operation, the fireplace stove warms up intensely. Therefore, the stove is attended employing a

protecting glove which is included in the scope of the delivery.

• Alert children to this danger, and take care that they may not linger in the vicinity of the stove when it is in

operation.

2.1. Safety instructions without RLU

• If the combustion air is taken from the living room, a sufficient input of fresh air must be secured in any case.

• The appliances for suction of air, such as ventilation appliances, fume hoods, laundry driers with discharge

of waste air etc., or other fire boxes must not exert a negative impact on the supply of air to the stove.

WARNING

The fireplace stove must not be brought into operation at the same time with the controlled ventilation
appliances in the flat.

2.2. Safety instructions with RLU

• For a tight chimney design (therefore, in the case of multiple recess of the chimney, it is not possible), the

stove match the FC41x type (for LAS system) and FC51C type, according to the approval criteria for solid
fuel heaters, independent of the room air of the Deutsches Institut für Bautechnik (DIBt) and to the DIN
18897-1 standard.

• In combination with technical devices for ambient air (controlled ventilation and exhaust ventilation devices,

kitchen hoods, exhaust fans, etc.) in Germany, the Section 4 of the Heaters Decree (FeuVo) is decisive.

Summary of Contents for EN13240

Page 1: ...rating manual Wood stoves EN13240 RLU C DIN 18897 EASY CONTROL Installation and operating manual Wood stoves EN13240 RLU C DIN 18897 EASY CONTROL GB 0415017001409b Wood stoves EN13240 RLU C DIN 18897 EASY CONTROL Nameplate ...

Page 2: ...ment sheet is part of these operating instructions Notes in the text Of utmost importance there are the notes entitled WARNING The notes entitled WARNING advise you on serious danger of damage to the heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note itself calls your attention to the information important for the operation of you...

Page 3: ...let of combustion air 4 4 3 Input connection of external air provided it is installed 4 5 Operation of the fireplace stove 4 5 1 Suitable fuels 4 5 2 Unsuitable fuels 5 5 3 First putting in operation 5 5 4 Ignition 5 5 4 1 Ignition with the air control EASY CONTROL 5 5 4 2 Ignition without the air control EASY CONTROL 6 5 5 Stoking of fuel 7 5 5 1 Chimney stove with EASY CONTROL 7 5 5 2 Chimney st...

Page 4: ......

Page 5: ...ned covered or blocked During the operation the fireplace stove warms up intensely Therefore the stove is attended employing a protecting glove which is included in the scope of the delivery Alert children to this danger and take care that they may not linger in the vicinity of the stove when it is in operation 2 1 Safety instructions without RLU If the combustion air is taken from the living room...

Page 6: ...y at nominal heating output of the stove min draft of the chimney from type 11 12 Pa If the minimum draft of the chimney is not achieved a proper operation of the stove is not possible Note At a low draft of the chimney we recommend to connect the chimney by a vertical tube 1 m long at least max draft of the chimney 20 Pa If surpassing the maximum admissible draft of the chimney there in creases t...

Page 7: ...tter of principle the fire places must be suitable and approved for multiple employment of the chimney 4 Emplacement 4 1 Minimum distances from inflammable construction parts CAUTION As a matter of principle the emplacement of a fireplace stove must observe the valid official fire fighting regulations In this respect please observe the international regulations WARNING Caution As minimum distances...

Page 8: ...ction of external air provided it is installed Note We recommend to employ an input connection of external air for the supply of combustion air so that precious air from the living room might not be consumed during heating WARNING We do not recommend to bring cold air from outside to the room by means of direct conduction it could bring about formation of condensate 5 Operation of the fireplace st...

Page 9: ...en für die Verbrennungsluftversorgung den Außenluftanschluss zu verwenden um nicht die wertvolle Wohnraumluft beim Heizen zu verbrauchen Es ist nicht empfehlenswert die kalte Luft über eine direkte Leitung von außen in den Raum zuzuführen da dies zur Bildung von Kondenswasser führen kann 5 Betrieb des Kaminofens 5 1 Geeignete Brennstoffe Die zur Verbrennung zugelassenen Brennstoffe sowie die max B...

Page 10: ... chimney As soon as complete fuel starts burning lively the lever is to be re set to Heating Ignition Heating Shut input of air WARNING During the operation regime of heating the lever must not be set to Shut input of air 0 it could bring about a sudden inflammation of fuel 5 4 2 Ignition without the air control EASY CONTROL First insert chunks onto the bottom of combustion chamber or onto the gri...

Page 11: ...f flue gases into the living space After having added fuel concerning the max admissible quantity close the firebox door shut again Next the regulation of primary and secondary air must be opened to maximum Once the fuel starts to burn the primary air regulator must be closed the secondary air regulator remains open Exception for secondary air control In the case of the Auto Air device function ev...

Page 12: ... boards The return draft boards can be taken out for cleaning see the specification of the appliance Glass of the door For ecological cleaning we dip a wet dishcloth in wood ashes and clean the glass with it Also it is possible to employ special cleaning agents for the glasses of fireplace stoves or regular agents for cleaning of glass without caustic acids and solvents It is also necessary to hav...

Page 13: ...l the chimney cleaning orifices that are not tight Have the draft of the chimney measured by the chimneysweep in charge Air slider for ignition open Position ON When the fuel starts burning lively set the slider for ignition to the po sition Heating operation regime The draft of the chimney too big min 20 Pa in the neck of com bustion products Have a draft limiter installed The door glass has milk...

Page 14: ...of the chimney adjusted improperly with reference to the appliance insufficient or too big unprofessional handling negligence or alterations of the appliance exclude guarantee claims too WARNING In case of any alteration in the construction of the stove as well as of its use contrary to the determined purpose all the rights arising from the guarantee cease to exist 9 Orders of spare parts question...

Page 15: ......

Page 16: ...uction as well as of technical and optical changes mistakes printing errors and faults in sentences You will find all documents as e g the Operation Manual specification of the appliance testing reports etc as well as the contact data also on www haassohn com ...

Reviews: