Dimensions and connection measurements
---------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------
Technical data
HSD 75.3 SF
------------------------------------------------
Dimensions
Device
*(excl. cover hood)
Oven
Fire door opening
Combustion area
Exhaust gas connector
Middle of exhaust gas connector-
floor
Weight
Minimum supply pressure
Nominal heat output
Efficiency
CO
Space heating capacity per DIN
18893
- with efficient installation
- with less efficient installation
- with inefficient installation
H/W/D mm
H/W/D mm
H/W mm
W/D mm
mm
mm
kg
mbar
kW
%
%
m3
m3
m3
850*/750/600
270/330/410
180/200
214/460
120
690
About 170
0.12
7.5
86.8
0.12
230
132
90
CЄ
inspection per standard
:
Inspection report no.: RRF 15 08 1779 EN 12815 Test centre: 1625
Remark:
Stoves that are not operated in slow combustion mode must have a 25% higher nominal heat output or
heat a 25% smaller space.
Connection options:Side and back – with the combustion, 1x up by steel plate
Accessories: poker, rake, baking tray, grate, cover hood (optional) Type of combustion: flat combustion
5
210