3.3. Connection to the chimney
• The tube of the smoke flue must be mounted on the neck of the discharge of combustion products.
• The tube of the smoke flue must not be installed with a gradient towards the chimney.
• There must be paid attention unconditionally that the tube of the smoke flue may not protrude into clear
diameter of the chimney; it would disturb the upward lift of the combustion products and would make
an optimum cleaning of the chimney more difficult.
• Longer horizontal sections of smoke flue tubes reduce the necessary draft of the chimney.
• All the orifices mouthed into the same chimney, such as cleaning orifices of the stove and of the
chimney, must be shut.
• In case of multiple employment of the chimney, the minimum vertical distance of two chimney
connections ought to be 30 cm at least. As a matter of principle, the fire places must be suitable and
approved for multiple employment of the chimney.
4. Emplacement
4.1. Minimum distances from inflammable construction parts:
CAUTION
As a matter of principle, the emplacement of a fireplace stove must observe the valid official fire-fighting
regulations.
In this respect, please observe the international regulations.
Caution! With a stove with lateral window, the same distance must be maintained as with the extent of
radiation in the front!
WARNING
Caution! As minimum distances from inflammable materials or materials sensitive to heat (e. g. furniture,
wallpapers, wooden linings), or load-bearing walls respectively, there must be respected the distances
shown in the type plate.
Bei brennbaren oder temperaturempfindlichen Fußbodenbelägen muss das Gerät auf eine nicht brennbare
Unterlage (z.B. Glasplatte) gestellt werden (siehe Zeichnung).