4
Recommended protection of the floor:
A 50 cm – in the front
B 30 cm – from the inside edge of the combustion space
C see the type plate – extent of radiation from the window
Safety distances from inflammable construction parts:
In the rear - see the type plate
On the side - see the type plate
In the front in the extent of radiation - see the type plate
4.2. Inlet of combustion air
It is necessary to ensure that in the place of location of the stove there would be available sufficient combustion air.
5. Operation of the fireplace stove
.
5.1. Suitable fuels
The fuels approved for combustion and the maximum stoking amounts of fuel are shown in the
specification of the appliance.
The length of the fuel varies from 29 cm to 33 cm, depending on the combustion chamber.
Orientating value (depending on the type of the wood):
1kg of fire wood = about 4kW
1kg of wood briquettes = about 5kW
Note
Wood briquettes expand during combustion, and therefore, they ought to be broken to pieces.
5.2. Unsuitable fuels
Never use for heating any waste, wallpapers, rests of chipboards, plastics or impregnated wood! When
combusting such materials, the appliance can suffer damage, by the consequence of which any guarantee
ceases to exist.
Summary of Contents for 0328315000000
Page 4: ......