5. Shutoff flue gas temp. in Heating mode too
low (21)
Cause:
•
Temperature fell below the minimum
temperature in Heating mode operating
status
The following circumstances might lead to this:
•
No pellets present
•
The screw conveyor is not rotating, it is
jammed, the screw conveyor motor is
defective or the chute is not clear
•
The required combustion air cannot be
supplied to the stove e.g. via a vapour
extractor hood that is located in the
vicinity of the installation site and is
switched on.
•
Room too airtight – required combustion
air cannot be replenished in the room
•
Air volume sensor dirty or defective
•
Suction filter dirty
•
Burner
dirty
•
Poor seals on the pellet stove (door,
seals)
•
Flame temperature sensor defective
•
Flue gas temperature sensor defective
Correction:
¾
Check pellet stock
¾
Check that the chute between the pellet
tank and the burner is clear.
¾
Clean the burner, suction filter and air
volume sensor (paintbrush).
¾
Check whether there is a vapour
extractor hood present and whether it is
in operation
¾
Make sure for instance that a window is
left open a crack to supply the required
combustion air
¾
Contact the service engineer
6. Shutoff flue temp. in Heating mode too
high (22)
Cause:
•
The highest permitted flue gas
temperature was exceeded
The following circumstances might lead to this:
•
Too much fuel is being supplied to the
burner
•
Flue gas temperature sensor defective
Correction:
¾
Contact the service engineer
7. Shutoff, combustion chamber door open
(6) or (9)
Cause:
•
The door is open for longer than 1 minute
during operation
•
The damper at the bottom of the door is
not in the right position
•
Cable broken in the electric wiring to the
door contact switch
•
The connector has come out on the door
contact switch or on the central unit
Correction:
¾
Close the door
¾
Move the damper at the bottom of the
door to the right position so that the
switch is operated when the door is
closed
¾
Check door contact switch, cable and
connector
8. Flue gas sensor interruption (7)
Cause:
•
Flue gas temperature sensor defective or
not connected
Correction
¾
Contact the service engineer
9. Flue gas sensor short circuit (8)
Cause:
•
Flue gas temperature sensor defective
Correction:
¾
Contact the service engineer
10.
Room temperature sensor interruption
(11)
Cause:
•
Room temperature sensor defective or
not connected
Correction:
¾
Contact the service engineer
11.
Room temperature sensor short circuit
(12)
Cause:
•
Room temperature sensor defective
Correction:
¾
Contact the service engineer
Correction:
¾
Contact the service engineer