25
back to “Standby” mode, the stove can no longer
be automatically ignited before the combustion
chamber has been cleaned.
To clean the combustion chamber, the stove has to
be switched to “Off” operating status.
If the combustion chamber is now cleaned, then
the “Clean combustion chamber” error message
will thereafter be cleared automatically. A
precondition for the automatic clearance of this
error message is that the combustion chamber
door is open for longer than 60 seconds in “Off”
operating status. This time is required for cleaning
the combustion chamber including the burner
thoroughly with an ash vacuum cleaner.
If the door is open longer than 60 seconds in “Off”
operating status, then the operating hours counter,
which is responsible for the “Clean combustion
chamber” instruction, is automatically reset to zero.
This reset of the operating hours counter occurs
even if the cleaning of the combustion chamber is
performed before the 50 operating hours have run
provided that the stove is in “Off” operating status
and the door is open for longer than 60 seconds
during cleaning.
21.
Error in parameters
Factory settings have been uploaded –
Fault has been cleared (60)
Cause:
•
Program
fault
•
Defective part in the operator console.
Correction:
¾
Contact the service engineer
22.
Backup battery empty
Cause:
•
Backup battery of the central unit is
empty
•
Backup battery not connected
Correction:
¾
Check
connection
¾
Replace backup battery
¾
Contact the service engineer
23.
LED board not connected (51)
Cause:
•
The connection between the LED board
and the central unit is interrupted.
The following circumstances might lead to this:
•
Connection cable is not connected to the
LED board or to the central unit or is
defective
Correction:
¾
Check that the connection cable is
connected to the LED board and to the
central unit
¾
Contact the service engineer
24.
Error – data transmission IO19 ( D3 )
Check cable (6000)
Cause:
•
No connection between operator console
and central unit
•
Component fault in the central unit
Correction:
¾
Check connection cable between
operator console and central unit
¾
Contact the service engineer
25.
Error – data transmission IO19 ( D5 )
Check cable (6001)
Cause:
•
No connection between operator console
and central unit
•
Component fault in the central unit
Correction:
¾
Check connection cable between
operator console and central unit
¾
Contact the service engineer
26.
Error – data transmission IO19 ( D6 )
Check cable (6002)
Cause:
•
No connection between operator console
and central unit
•
Component fault in the central unit
Correction:
¾
Check connection cable between
operator console and central unit
¾
Contact the service engineer
27.
Error, Amtel version ( D3 ) (6100)
Cause:
•
Component fault in the central unit
Correction:
¾
Contact the service engineer
28.
Error, Amtel version ( D5 ) (6101)
Cause:
•
Component fault in the central unit
Correction:
¾
Contact the service engineer