background image

Art. Nr.0618719009033 

V12 E30 

Connection for providing the air needed for combustion: 

In airtight buildings there can be reduction in the oxygen content of the room in which the stove is set up; it must 
therefore be ensured that there is adequate ventilation. The stove unit type Aqua 187.19-WT therefore offers you 
the possibility of drawing in the air needed for combustion from outside. The stove can then be operated without 
having to depend on the air within the room. In order to do this the air from outside that is needed for combustion 
is supplied by means of a flexible pipe attached to the socket for the pipe (10). It is possible for you to change the 
position of the pipe socket to the left, right or rear of the stove unit.

 

The end of the pipe carrying the air must be 

located  in  the  open  air,  or  in  a  well  ventilated  room  situated  within  the  building.  Operation  of  the  stove  unit  in 
connection  with  an  air  conditioning  and  ventilation  system  is  permitted.  When  installing  the  stove  unit  in 
connection with an automatic air conditioning and ventilation system the end of the pipe supplying the air must not 
be located in a room which is connected to this system. 

 

The amount of fuel and adjustment of the air intake control: 

Lighting, and heating the appliance up: see sections 11 in the instructions for use of the stove. 
Use the gloves provided to protect you against the heat when operating the air intake control. 
Before every addition of fuel, the air intake control is to be closed completely. 
 

 
 
 
 
 
 
 

Tip for burning wood:

 

Every time the stove is lit leave the appliance in the ‘open’ position until 

the fuel is burning well (around 10 minutes). This time can vary somewhat depending on the 
amount of draught and the pressures involved.  

 

Specification plate: 

 

 

Nennwärmeleistung

Wärmeleistung/Wärmetauscher

Zugelassener Brennstoff:

Staub bez.auf % O

2: 30 

mg/Nm³

Wirkungsgrad:90,5%

CO:0,05%

Prüf Nr. VKF: 

NOx: 106 mg/Nm³

HC:  23 mg/Nm³

Abgastemperatur :

166°C

Mindestabstände 

seitlich:

40 cm

zu brennbaren Bauteilen:

hinten:

40 cm

vorne im Strahlungsbereich:

80 cm 

Anbringungsjahr

Lesen und befolgen Sie die Bedieungsanleitung!

Mehrfachbelegung des Schornsteins ist zulässig

Betriebsdruck max. 3,0bar

2011

17,0 kW

Holz, Holzbrikett nach -DIN 51731, Braunkohlebrikett

Prüfstellenkennziffer: 1015 / Prüf Nr.30-11150 

10,8 kW

 Herstellnummer:

1103187901650

Wärmeleistungsbereich:

5,1- 17,4 kW

HAAS + SOHN  OFENTECHNIK GMBH

URSTEIN NORD 67    A-5412 PUCH

Kamineinsatz Bauart: EN13229 / Zeitbrandfeuerstätte

Typenbezeichnung:

187.19-WT

 

 

Prüf. Nr. 

Stove unit Aqua 187.19-WT / EN 13229 
Testing code : 1015 

Inspection no.: E 30 - 11150 

 

Fuels 

Amount of fuel 

Primary air: air intake control (6) 

Secondary air (7) 

Chopped wood 
Wood briquettes: 

5 -6 pieces of wood  

(approx 4 -4,5 kg) or 

 2 wood briquette (4 kg) 

For approximately 10 minutes: open  

 (handle to the left) 

open 

Lignite 
briquettes: 

5 -6 briquettes 

open 

position 1 

 
 
 

Summary of Contents for AQUA 187.19-WT

Page 1: ...Art Nr 0618719009033 V12 E30 1 Installation and operating manual HAAS SOHN AQUA 187 19 WT Art Nr 0618719000000 ...

Page 2: ...ir 0431317006601 29 Air intake control 10 Outside air pipe fitting ø120 30 Heat sensor 0431815025310 11 Door handle mounting 31 senor discharge safety device 0426817015320 12 fire chamber door handle 0618018035301 13 Glass pane 0040220040005 Seal heat exchanger 20x4 2120 mm 0618018025301 14 Glass pane 0040710100005 Seal fire chamber door 10 2220 mm 0618018075701 15 Lower draft deflection plate 004...

Page 3: ...the air intake control 6 With the handle in position 1 left the primary air I The amount of secondary air is set at an optimum level for the unit to provide the necessary ventilation to keep the window clean and to provide the necessary air for secondary combustion and adjustable from 0 2 The pre heated secondary air flows past the top end of the inspection window 8 The injector air 9 is permanent...

Page 4: ...the stove Use the gloves provided to protect you against the heat when operating the air intake control Before every addition of fuel the air intake control is to be closed completely Tip for burning wood Every time the stove is lit leave the appliance in the open position until the fuel is burning well around 10 minutes This time can vary somewhat depending on the amount of draught and the pressu...

Page 5: ...Art Nr 0618719009033 V12 E30 5 ...

Page 6: ...Art Nr 0618719009033 V12 E30 6 Mounting adjustable feet and sensor overheat protection ...

Page 7: ...075401 2 stone on side left 1 0618018075501 3 stone on side right 1 0618018075502 4 stone lower 1 0618018075505 5 stone left 1 0618018075506 6 stone right 1 0618018075507 7 stone rear right 2 0618018075508 8 stone rear left 2 0618018075509 9 stone rear top 1 0618018075511 A draft deflection plate 1 0618018075701 B grating 1 0618018075070 C upright grating 1 0618618015820 D ash pan 1 0618018075410 ...

Page 8: ...mm Fuel Wood Wood briquette lignite briquettes Rated heating capacity 17 kW CO2 12 45 9 15 7 22 Thermal output range 5 1 17 4 kW Efficiency 90 5 86 7 84 Heat emission WT 10 8 kW supply temperature max 95 C Volume water ca 74 l Return lifting 50 C is prescribed storage pressure max 3 0 bar Inspection no EN 13229 E 30 11150 ET Nr Pos Bezeichnung 0618018076020 1 safety heat exchanger 0618018076016 2 ...