The stove is in waiting condition. Before it can be switched over from the operating setting "standby" to the
operating setting "Start zones 1 – 20", two conditions for the start are to be fulfilled:
• The "Actual room temperature" must drop under the "Setpoint temperature" by 1 °C at least
• The temperature of the combustion products measured by temperature sensor must be lower than 70 °C
11.8. Shut down
If a fault occurs, then a shut down is initiated. The components are switched on or off as follows:
• Induced draught fan – ON and Screw conveyor – OFF and Ignition – OFF
11.9. Cooling
The end of the shut down process depends on time and temperature.
11.10. Error display - Fault
The stove can no longer be automatically started up. The operator
can see the fault on the display. Once the fault has been properly
corrected and the error message on the operator console has been
cleared, the stove can be started up again.
Procedure:
The error is cleared by pressing the
"OK"
button.
Welcome page is displayed.
Combustion chamber door
open
F0009
OK
Note
Otherwise please read the information under Faults, causes, correction.
11.11. OFF
12. Overheating protection
A safety temperature limiter (STL) automatically switches the stove off if it overheats. The error F001 is shown
on the console display under operating status. In this case, the appliance must be inspected by a qualified
technician!
13. Power cut
The control unit has a backup battery so that data is retained during a power cut.
A distinction is made between a short power cut and a long power cut.
Short power cut – lasts for less than about 30 seconds: