GB
12
Note
During the
"Burner test"
, the level of contamination is measured using the pressure difference sensor.
If the limit value is not exceeded, the start process is initiated.
The display now shows
"Start zone"
. The indicator shows the prog-
ress of the start.
Start zone
03
Setpoint temperature
Note
By pressing
"ON/OFF"
button again, the stove is switched back off. The button on the display turns grey.
The stove performs the ENTIRE start zone, however, until it reaches the necessary flame temperature and
only then switches to the cooling Operating status and then OFF.
WARNING
During the first use, odours and smoke arising from paint applied to stove may build up for a short time. Please
ensure that there is adequate ventilation in the installation room during this time and avoid inhaling directly!
The varnish is prone to scratches and damage before commissioning, but hardens after repeated heating.
Note
If the start zone could not be successfully completed i. e. no flame generation or the required temperature
could not be reached at the flue gas thermosensor, then a safety shutdown is initiated and an error message
generated ("Error 2 – Date and time"). Before starting again, empty the burner and replace it.
8. Additional operator console functions
8.1. Backlighting
The backlighting of the display is switched off 5 minutes after the operator console was last operated and
switches to energy saving mode.
The backlighting is switched on by pressing on button. The function buttons are only active once the
backlighting has been activated. The backlighting is also activated by an error message being triggered.