GB
26
F. Screw motor defective
G. Pellet fuel has too low a calorific value
D. Clean burner - Ensure adequate
combustion air
E. Flue gas temperature sensor defective -
contact service department
F. Screw motor defective - contact service
department
G. Clean burner - switch to high quality pellet
type
F0006
A. Combustion chamber door open during
operation
B. Damper in front of the door contact switch
not in the right position
C. Cable broken in the electric wiring to the
door contact switch
D. The connector has come out on the door
contact switch or on the central unit
A. Clean burner - close door
B. Clean burner - Adjust damper in front of the
door contact switch
C. Cable broken on door contact switch -
contact service department
D. Contact service department
F0007
A. Flue gas temperature sensor defective or
not connected
A. Contact service department
F0008
A. Flue gas temperature sensor defective
A. Contact service department
F0009
A. Note: Combustion chamber door open
during "Off or standby"
A. No correction necessary - Close door -
Error is automatically cleared
F0011
A. Room temperature sensor defective or not
connected
A. Contact service department
F0012
A. Room temperature sensor defective
A. Contact service department
F0015
A. Induced draught fan defective
B. Power supply to the fan motor interrupted
A. Contact service department
B. Check cable - contact service department
F0018
A. Power cut
A. Clean burner - Clear error 018
F0019
A. Burner dirty - (when heating)
B. Leakage
C. Flue draught too low
A. Clean burner tray
B. Check doors, ashtray doors, seals
C. Check the chimney
F0020
A. Burner dirty (at burner test when heating)
B. Leakage
C. Flue draught too low
A. Clean burner tray
B. Check doors, ashtray doors, seals
C. Check the chimney
F0021
A. Burner dirty
B. Pellet tank empty
C. Downpipe / screw conveyor blocked
D. Room too airtight – required combustion air
cannot flow into the room
E. Flue gas temperature sensor defective
F. Screw motor defective
G. Pellet fuel has too low a calorific value
A. Clean burner
B. Clean burner - fill pellet tank
C. Clean the intake on the screw conveyor
housing with a vacuum cleaner. – Clean
burner
D. Clean burner - Ensure adequate
combustion air
E. Flue gas temperature sensor defective -
contact service department
F. Screw motor defective - contact service
department
G. Clean burner - switch to high quality pellet
type
F0022
A. Flue draught too low
B. Flue draught too high
C. Burner dirty
D. Flue tube pipeline too long (horizontal)
E. Flue gas temperature sensor defective
A. Measure flue draught - contact service
department
B. Measure flue draught - contact service
department
C. Clean burner