GB
1
1. Technical data
HSP 6 537.08–WT RLU/PGI
Heat output range:
2,7 – 10 kW
Nominal heat output:
10 kW
Output delivered by the stove body only (NO/PO):
2,1/0,2 kW
Output available for heating of water (NO/PO):
7,9/2,5 kW
Height:
1200 mm
Width:
545 mm
Depth:
498 mm
Weight:
174 kg
Diameter of flue elbow:
80 mm
Flue gas temperature:
148 °C
Testing transport pressure at nominal output:
12 Pa
Testing transport pressure at partial output:
5 Pa
Flue gas flow rate in g/s
6,1 g/s
CO level in flue gas (%) (min./max.)
0,01/0,03 %
Efficiency (NO/PO):
94/98 %
CO level in flue gas:
150 mg/Nm³
NOx level in flue gas:
102 mg/Nm³
OGC level in flue gas:
<5 mg/Nm³
Proportion of dust in flue gas:
20 mg/Nm³
Contents of storage container (pellet tank):
about 32 kg
Duration of burn with one charge (min./max.):
about 15 h/60 h
Permitted fuel: Low-dust wood pellets
diameter: 6 mm
to Ö-Norm M 7135, DIN plus, EN plus-A1
length: max. 30 mm
Room heating capacity to DIN 18893, constant heating:
340m³/220m³/130m³
Room heating capacity to DIN 18893, timed heating:
225m³/132m³/90m³
Electricity supply:
230 V (50 Hz)
Electricity supply input:
in normal operation:
max. 85 W
Electric ignition (for max. 15 minutes on ignition):
max. 660 W
Electronics fuses: (F3)
T 0,315 A, 250 V
Fuses for the ignition, screw conveyor motor, induced draught, (F1), pump
(F2)
T 3,15 A, 250 V
Maximum operating over-pressure of the exchanger:
200 kPa (2 bar)
Water contents of the exchanger:
30 l
Nominal flow rate:
315 l/h
Pressure loss at nominal flow rate:
130 mbar
Safety distances
Minimal distances from flammable materials:
side:
10 cm
rear:
5 cm
front (radiation area):
80 cm
Summary of Contents for HSP 6 537.08-WT RLU/PGI
Page 4: ......
Page 6: ...Dimensions GB 2 2 Dimensions 2 1 Dimensions...
Page 11: ...Maintenance work GB 7 Figure 1...
Page 14: ...Maintenance work GB 10 Figure 3a...
Page 15: ...Maintenance work GB 11 Figure 3b...
Page 18: ...Maintenance work GB 14 Figure 4...
Page 19: ...Maintenance work GB 15 Figure 5 Removing the side wall...
Page 26: ...Circuit diagram GB 22 6 Circuit diagram Circuit diagram IO 33 6...
Page 28: ......