14

 

10.2. Heating mode 

After the positive conclusion of the “Start phase”, the stove automatically switches to “Heating mode”. 

In  “Heating  mode”,  the  heat  output  of  the  stove  is  adjusted  in  modular  fashion  to  the  room  temperature  or  to  the 
difference between the ACTUAL and TARGET room temperatures. 

If  the  difference  between  the  ACTUAL  and  TARGET  room  temperatures  is  big,  then  the  stove  heats  with  a  bigger 
heat output. 

The  nearer  the  ACTUAL  and  TARGET  room  temperatures  get  to  each  other,  the  more  the  stove's  heat  output  is 
reduced. 

10.3. Burner test (burner cleaning) 

During  the  “Heating  mode”  operating  status,  an  automatic  burner  cleaning  process  is  carried  out  at  regular  time 
intervals (e.g. 30 minutes). 

This process takes approx. 2 minutes. 

10.4. Cooling down  

If  the  set  TARGET  room  temperature  is  reached  or  the  “ON/OFF”  button  is  pressed,  then  the  operating  status 
switches to “Cooling down”. 

The cooling down phase is restricted by timing control (duration about 15 minutes). 

After the end of the “Cooling down” operating status, the appliance switches to “Standby” operating status or “OFF”. 

10.5. ECO mode 

Eco mode means continuous operation at a low output, if the “ACTUAL room temperature” is higher than the set 
“TARGET room temperature” i.e. the stove does not switch off but continues to run on a “smaller flame”. 
 
If the set “TARGET room temperature” is exceeded by more than 2°C in eco mode despite a small flame,  

 

eco mode is automatically switched off and the stove switches to the “Cooling down” operating status. 

 

Eco mode function is automatically deactivated. 

 
If an “ACTUAL room temperature” of 30°C is exceeded in eco mode,  

 

eco mode is automatically switched off and the stove switches to the “Cooling down” operating status. 

 

Eco mode function is automatically deactivated. 

10.6. Standby 

The stove is in a waiting position 

Before the stove can switch from “Standby” back to the “Start zone 1-20” operating status, two start conditions must 
be fulfilled: 

 

The ACTUAL room temperature must be at least 1.0 °C below the set TARGET room temperature 

 

The flue gas temperature measured with the flue gas thermosensor must be less than 70 °C 

 

10.7. Switch-off 

If a fault occurs, then a switch-off is initiated. The components are switched on or off as follows: 

 

Induced draught fan – ON  

 

Screw conveyor – OFF 

 

Ignition – OFF 

10.8. Cooling down 

The end of the switch-off process depends on time and temperature. 

Summary of Contents for HSP 6 PALLAZZA-III 519.08

Page 1: ...PELLET STOVE Nameplate Aufstellungs und Bedienungsanleitung Pelletofen DE Fiche descritive Poele FR Schema tecnica strufa Camino IT Equipment sheet Fireplace GB Tshnicki podaci Kaminsku HR Podatkovni...

Page 2: ...8 2 Energy saving mode ACTUAL room temperature display 9 8 3 Button lock child safety device 9 9 Functions in the main menu 9 9 1 Main menu Select functions 9 9 1 1 Operating mode Week program Settin...

Page 3: ...tricted covered or shut off On stoves with an outdoor air connection the opening must not be shut or closed during operation Make children aware of these dangers and keep them away from the fireplace...

Page 4: ...flue tube does not stick out into the open cross section of the chimney which would interfere with the flue gases rising and prevent the optimal cleaning of the chimney The use of wall lagging is rec...

Page 5: ...recommended to feed the cold air into the room from outside via a direct duct as this can lead to the build up of condensation In order to guarantee a sufficient supply of air the duct should not be l...

Page 6: ...iameter Identification DINplus Norm M 7135 ENplus A1 7 2 Unsuitable fuels The use of lower quality or unauthorised fuel adversely affects the operation of your pellet stove and may lead to the lapse o...

Page 7: ...its mounting Close the combustion chamber door Fill the storage container with pellets Plug in mains cable Tip Only when using for the first time place approx 30 pellets in the burner This speeds up t...

Page 8: ...er until it reaches the necessary flame temperature and only then switches to the cooling operating status and then OFF During the first use odours may build up for a short time Please ensure that the...

Page 9: ...ctivation Hold the Menu button down for approx 10 seconds until Button block activated no longer appears on the display 9 Functions in the main menu 9 1 Main menu Select functions OK language english...

Page 10: ...tch on time can now be set with the Plus or Minus buttons The switch off time on the respective week day can be programmed by pressing the right hand arrow button The required room temperature is sele...

Page 11: ...with the Plus or Minus buttons The setting is saved by pressing the OK button To exit the function press the On Off button 9 1 4 Heating curve How it works h003 OK 2 2 main menu heating curve set fac...

Page 12: ...given on the WLAN module operating instructions 9 1 7 Fill manually Optional only on HSP8 on screw conveyor off main menu Fill manually Procedure Place the cursor in the main menu on Fill manually Pr...

Page 13: ...the START of the respective test setting 10 Operating statuses 10 1 Start Zone 1 20 Start phase The start phase begins if the current room temperature falls below the set target temperature by 1 C the...

Page 14: ...CO mode Eco mode means continuous operation at a low output if the ACTUAL room temperature is higher than the set TARGET room temperature i e the stove does not switch off but continues to run on a sm...

Page 15: ...p battery so that data is retained during a power cut A distinction is made between a short power cut and a long power cut Short power cut The short cut lasts for less than about 30 seconds Once the e...

Page 16: ...tive G Pellet fuel has too low a calorific value A Clean burner B Clean burner fill pellet tank C Clean the intake on the screw conveyor housing with a vacuum cleaner Clean burner D Clean burner Ensur...

Page 17: ...alorific value E Downpipe screw conveyor blocked F Room too airtight required combustion air cannot flow into the room G Flame temperature sensor defective H Screw motor defective A Fill pellet tank B...

Page 18: ...eals seals of any kind handles invalidate a warranty Maintenance or cleaning not performed or performed inadequately a flue draft that is incorrectly set to the appliance or is insufficient or too hig...

Reviews: