Maintenance

work

GB

8

4.2. Cleaning the pellet container - annual maintenance

• Heat the pellet stove until the storage tank is completely empty.

• Then the protective grille (1) in the pellet tank may be removed.

• Then clean the tank and the intake of the screw conveyor housing with a vacuum cleaner.

• After cleaning, it is essential to put back the protective grille. When doing this, make sure that no screws fall

into the pellet tank so as to avoid consequential damage to the screw conveyor.

Figure 3: Pellet tank

1 Protective grille
2 Tank cover

Summary of Contents for HSP 6 Pallazza III 535.08-PGI

Page 1: ...HSP 6 Pallazza III 535 08 PGI Equipment sheet Pellet stove GB 0553508021413a Equipment sheet HSP 6 Pallazza III 535 08 PGI...

Page 2: ...he heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note entitled Important calls your attention to the information important for the o...

Page 3: ...instruction Error F040 3 3 4 Cleaning the combustion pot weekly 3 4 Maintenance work 5 4 1 Cleaning the flue gas passes 5 4 2 Cleaning the pellet container annual maintenance 8 5 Replacement parts li...

Page 4: ......

Page 5: ...ntents of storage container pellet tank about 32 kg Duration of burn with one charge min max about 20 h 60 h Permitted fuel Low dust wood pellets Diameter 6 mm to Norm M 7135 DIN plus EN plus A1 Lengt...

Page 6: ...Dimensions GB 2 2 Dimensions...

Page 7: ...stion chamber function instruction Error F040 The whole combustion space must be cleaned after 30 hours operation at the latest or once a week The requirement to clean the fire box flickering of the d...

Page 8: ...ring in the pellet tank might possibly result This will destroy your device and is not covered in your guarantee WARNING Cleaning the combustion pot may only be done with a cooled down stove in OFF op...

Page 9: ...content is higher 0 5 and over the interval from maintenance to maintenance is reduced and the accumulation of ash increases by 2 or 3 times WARNING Devices that are not maintained in accordance with...

Page 10: ...Maintenance work GB 6 Figure 1 Removing the flue baffle...

Page 11: ...ork GB 7 Figure 2 Removing the side wall CAUTION After completion of the cleaning make sure that when putting back the covers the seals are seated in the right positions It is essential to replace def...

Page 12: ...1 in the pellet tank may be removed Then clean the tank and the intake of the screw conveyor housing with a vacuum cleaner After cleaning it is essential to put back the protective grille When doing t...

Page 13: ...Replacement parts list GB 9 5 Replacement parts list 5 1 Replacement parts list Pallazza III 535 08 PGI without trim parts...

Page 14: ...ery CR 2032 1 piece 13 Stand 4 piece 0551908505005 14a Ignition 1 piece 0541908005202 14b Lighter case 1 piece 0553808005215 15 Room temperature sensor 1 piece 0089500390005 16 Flue gas thermosensor 1...

Page 15: ...37 Screw UN5950 M5x10 4 piece 38 Air hose 1 piece 0551908015315 5 2 Detail A1 Pos Description Piece No PR Detail A1 A1 1 Screwing door Set 1 piece 0551908005001 A1 2 Door hinge Set 1 piece 0551908005...

Page 16: ...parts list Pallazza III 535 08 PGI 43 Side wall rear right 1 piece 0553408025500 44 Side part C ceramic white right 1 piece 0553208126185 45 Side wall front right 1 piece 0553408026300 46 Front plate...

Page 17: ...Circuit diagram GB 13 6 Circuit diagram Circuit diagram IO 33 3...

Page 18: ...onveyor motor 7 Induced draught 8 9 OC 35 36 Flue gas temperature sensor 37 38 Flame temperature sensor 39 40 Room temperature sensor 41 42 Bottom flame temperature sensor 43 44 Door contact switch 48...

Page 19: ......

Reviews: