HSP 7 Diana 450.08
Heat output range:
2,4 – 8,2 kW
Nominal heat output:
8,0 kW
Height:
1053 mm
Width:
494 mm
Depth:
494 mm
Weight:
125 kg
Diameter of flue elbow:
80 mm
Flue gas temperature:
197 °C
Testing transport pressure at nominal output:
12 Pa
Testing transport pressure at partial output:
6 Pa
Flue gas flow rate in g/s
5,6 g/s
CO level in flue gas (%) (min./max.)
0,01/0,03 %
Efficiency:
90/94 %
CO level in flue gas:
138 mg/Nm³
NOx level in flue gas:
131 mg/Nm³
OGC level in flue gas:
5 mg/Nm³
Proportion of dust in flue gas:
17 mg/Nm³
Contents of storage container (pellet tank):
about 12 kg
Duration of burn with one charge (min./max.):
about 7 h/22 h
Permitted fuel: Low-dust wood pellets
diameter: 6 mm
to Ö-Norm M 7135, DIN plus, EN plus-A1
length: max. 30 mm
Room heating capacity to Ö-Norm M 7521:
max. 230 m³
Room heating capacity to DIN 18893, constant heating:
250m³/145m³/98m³
Room heating capacity to DIN 18893, timed heating:
165m³/95m³/65m³
Electricity supply:
230 V (50 Hz)
Electricity supply input:
in normal operation:
max. 50 W
Electric ignition (for max. 15 minutes on ignition):
max. 380 W
Electronics fuses: (F3)
T 0,315 A, 250 V
Fuses for the ignition, screw conveyor motor, induced
draught, (F1):
T 3,15 A, 250 V
Safety distances
Minimal distances from flammable materials:
side:
10 cm
rear:
10 cm
front (radiation area):
80 cm
Summary of Contents for HSP 7 Diana 450.08
Page 4: ......
Page 6: ...Dimensions GB 2 2 Dimensions ...
Page 10: ...Maintenance work GB 6 Figure 1 Removing the flue baffle ...
Page 11: ...Maintenance work GB 7 Figure 2 Removing the cleaning cover ...
Page 12: ...Maintenance work GB 8 Figure 3 Removing the side wall ...
Page 19: ...Circuit diagram GB 15 6 Circuit diagram Circuit diagram IO 33 3 ...
Page 21: ......
Page 22: ......
Page 23: ......