6
4.2. Cleaning the flue gas passes - annual maintenance
CAUTION
We therefore recommend checking and/or cleaning the flue gas passes after 1,000 kg of pellets at the latest.
To clean the flue gas passes, proceed as follows:
• Disconnect the flue baffle (1) from the guide by lifting it. Draw the right cladding (2) down out of the guide
and place it down in the ash space. Then the flue baffle can be removed and the upper part of the
combustion chamber can be cleaned. (See Figure 8a).
• Then remove the right side wall. This is fixed with screws (1) at the back and at the front with 3 connectors.
Remove the screws from the back and pull the side wall off sideways. (See Figure 8b).
Figure 8a: Removing the flue baffle
Summary of Contents for HSP 8 Lucca-II-RLU 442.08-ST