Fuse Check / Replacement

Verify Machine Operation

Power on the machine.

Zero Return and verify that there are no alarms generated during this process.

If alarms occur, check the fuse again and check for a short circuit in the axis drive system. Refer to the

following troubleshooting guides:

SIGMA 5 - AXIS SERVO MOTOR AND CABLES - TROUBLESHOOTING GUIDE

SERVO AMPLIFIER - TROUBLESHOOTING GUIDE

HIGH VOLTAGE 320V POWER SUPPLY (MMPS) - TROUBLESHOOTING GUIDE

Turn off the main circuit breaker.

Danger:

Do not discharge the power supply

using a resistor, this will cause the fuse to blow.

Wait until the HV light [1] on the 320V Power

Supply turns off.

The fuse [2] is inside the 320V Power Supply.

Remove the old fuse from the fuse holder [3].

Set the multimeter [4] to Ohms.

Probe the metal ends of the fuse.

Replace the fuse if the multimeter reads open

(O.L).

320V Power Supply (MMPS) - Fuse Replacement - AD0446

Page 2 of 2 pages