ES0755 rev A 1/11
31
NOTE
: On a machine with a safety circuit, the chip auger will only run with
the door closed regardless of the Conveyor Door Override bit.
t
hrouGh
the
s
Pindle
c
oolant
(tsc) s
ystem
Warning!
The TSC pump is three phase and must be phased correctly!
Improper phasing will damage the TSC pump and void the warranty.
1. Fill the coolant tank with coolant and connect all hoses and power cords. Zero Return the machine.
2. Press the MDI button and turn on TSC by pressing the AUX CLNT button. Quickly go to the back of the
machine and check if the TSC pump motor is turning and pushing coolant through the clear intake hose. If it
is, the machine is properly phased. If not immediately stop the pump by pressing the RESET button. Check
that the intake hose connection is tight, the connection must be tight for the pump to prime itself. If the motor
is not turning, check that the power cords are connected and the circuit breaker inside the control box is on.
The TSC pump will not pump if it is rotating backwards. The motor rotation should be clockwise when viewed
from the fan end.
CAUTION: Running The TSC pump dry for more than 60 seconds can cause serious damage to the pump.
3. If the machine is improperly phased perform the following procedure:
a. Turn off the power to the input side (top) of the main circuit breaker. Measure the Voltage!
b. Exchange any two wires at the input side (top) of the main circuit breaker as shown.
c. Close the control box. Return to Step 2 and test for proper phasing.
Main
Circuit
Breaker
Ground
Line
L1
L2 L3
o
Ptional
a
uxiliary
f
ilter
for
tsc s
ystem
Installation
1. Hang the auxiliar.y filter assembly from the coolant tank handle and secure it with two 1/4-20 screws as
shown.