ES0755 rev A 1/11
34
NOTE
: When inserting the pendant pivot into the pendant pivot block,
make sure the pendant arm is perpendicular to the table, as shown
in the figure below.
Table Cable Trough
Pivot Block
Top Cover
Pendant Pivot Block
4. Place the table cable trough on the floor. Arrange the pendant wiring through the pendant pivot
block and into the trough. Slide the trough under the mill table.
5. Move to the opposite side of the table (chip auger side). Remove the 1/4-20 BHCS from the
trough cover and remove the cover. Snip the cable ties and unroll the control cabinet wiring into
the trough.
6. Attach the trough extension to the flange of the table bed. Route the cables from the table cable
trough up into the trough extension. Connect the cable ends from the pendant to the cable ends
from the control cabinet.
7. When the proper cable connections have been made, attach all the trough covers to the trough
assembly using 1/4-20 BHCS.
8. Attach the table cable trough to the table and secure with 1/4-20 BHCS.
9. Move to the pendant side of the table. Attach the table cable trough to the bottom of the pendant
pivot block using 1/4-20 BHCS.
10. Attach the pivot block top cover to the pendant pivot block. Secure with 1/4-20 BHCS.