Section 2
Symptom:
Alarm
151
LOW THROUGH SPINDLE COOLANT.
Possible Cause:
Incorrect power phasing - the pump motor is
running backwards.
Corrective Action:
The power supply PCB has a phase detect with neon indicators
on the top center portion of the board. Make sure that the
electrical power is phased correctly:
Green Light:
The incoming power is phased correctly.
Orange Light:
The incoming power is incorrectly phased.
Both Lights:
A phase is missing (there is a loose cable in the
system).
If the electrical power is phased incorrectly:
Set the main circuit breaker on the machine to the OFF position.
Lock the main circuit breaker. Use an approved lock with an
approved safety tag.
Swap the #74 and #75 incoming power cables at the main
transformer.