96-8100
1-15-96
178
PARAMETERS
S E R V I C E M A N U A L
VF-S
ERIES
20. PARAMETERS
Parameters are seldom-modified values that change the operation of the machine. These include servo motor
types, gear ratios, speeds, stored stroke limits, lead screw compensations, motor control delays and macro call
selections. These are all rarely changed by the user and should be protected from being changed by the
parameter lock setting. If you need to change parameters, contact HAAS or your dealer. Parameters are pro-
tected from being changed by Setting 7.
The Settings page lists some parameters that the user may need to change during normal operation and these
are simply called Settings. Under normal conditions, the parameter displays should not be modified. A com-
plete list of the parameters is provided here.
There are 226 parameters in this control. The first 56 apply to the individual servo axes, 14 each. The first 14 of
these will be described. The other axes parameters (15 through 56) are identical in function.
PARAMETER LIST
Parameter
1
X SWITCHES
Parameter 1 is a collection of single-bit flags used to turn servo related
functions on and off. The left and right cursor arrows are used to select the
function being changed. All values are 0 or 1 only. The function names are:
REV ENCODER
Used to reverse the direction of encoder data.
REV POWER
Used to reverse direction of power to motor.
REV PHASING
Used to reverse motor phasing.
DISABLED
Used to disable any axis.
Z CH ONLY
With
A
only, indicates that no home switch.
AIR BRAKE
With
A
only, indicates that air brake is used.
DISABLE Z T
Disables encoder
Z
test (for testing only).
SERVO HIST
Graph of servo error (for diagnostics only).
INV HOME SW
Inverted home switch (N.C. switch).
INV Z CH
Inverted
Z
channel (normally high).
CIRC. WRAP.
(
Future Option - Not Yet Implemented)
With
A
only, causes 360 wrap to
return to 0.
NO I IN BRAK
With
A
only, removes
I
feedback when brake is active.
LOW PASS +1X
Adds 1 term to low pass filter.
LOW PASS +2X
Adds two terms to low pass filter.
OVER TEMP NC
Selects a normally closed overheat sensor in motor.
CABLE TEST
Enables test of encoder signals and cabling.
Z TEST HIST
History plot of Z channel test data.
SCALE FACT/X
If set to 1, the scale ratio is interpreted as divided by
X; where X depends on bits SCALE/X LO and SCALE/X HI.
INVIS AXIS
Used to create an invisible axis.
ROT ALM LMSW
Rotary alarms at the limit switch.
ROT TRVL LIM
Rotary travel limits are used.
UNDEFINED
UNDEFINED
UNDEFINED
TORQUE ONLY
For HAAS only.
Summary of Contents for VF-SERIES
Page 180: ...1 15 96 96 8100 177 TABLEOFCONTENTS TECHNICAL REFERENCE SERVICE M A N U A L VF SERIES ...
Page 235: ...96 8100 1 15 96 232 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 COLUMN ...
Page 237: ...96 8100 1 15 96 234 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 1 LEADSCREW ...
Page 239: ...96 8100 1 15 96 236 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 COLUMN ...
Page 241: ...96 8100 1 15 96 238 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS VF 3 LEADSCREW ...
Page 245: ...96 8100 1 15 96 242 VF SERIES S E R V I C E M A N U A L ASSEMBLY DRAWINGS 3 4 2 1 ...