background image

i

About This Manual

This manual uses special attention icons to alert the reader of important 

safety concerns, information important to reliable operation of the controls 

or helpful installation/setup information. 

Safety:

 Indicates a condition which may cause severe personal 

injury, death, or major property damage.

Important Information:

 Indicates information which requires 

special attention for correct operation of the control.

Your Benefit:

 Indicates helpful installation or setup information.

For installation and instructions, refer to the 

Installation & Pairing Manual.

 

 

For programming instructions, refer to the  

Programming Guide

 

 

 

 

 

 

 

        

Documentation

Summary of Contents for HTE-01

Page 1: ...Operation Manual Smarter Control Solutions...

Page 2: ...Indicates a condition which may cause severe personal injury death or major property damage Important Information Indicates information which requires special attention for correct operation of the co...

Page 3: ...m Overview 1 2 Home Screen Display Controls 3 7 HTE 01 Thermostat Operation 8 14 Changing Operating Mode 8 Changing Fan Speed 9 Alarm Operation 10 Compressor Short Cycle Protection Cooling Fan Delay 1...

Page 4: ...ly 50 feet through standard building materials PTAC Packaged Terminal AC WSHP Water Source Heat Pump HWSHP Hybrid Water Source Heat Pump FCU Fan Coil Mini Split Unit UNI Unitary AC Furnace The The HTE...

Page 5: ...s over to Heat OFF O Heating is default switches over to Cool If more than one appliance type dip switch 1 5 is selected error code will be displayed System Overview Dip Switch Configurations 1 PTAC P...

Page 6: ...3 Home Screen 1 2 3 4 5 6 7 9 10 11 12 13 14 8...

Page 7: ...dicator status only shown when on battery power used Full Half Low Replace 10 Schedule running indicator Schedule Schedule running1 Blank No Schedule 4 System type 11 Set point 5 Room temperature 12 C...

Page 8: ...5 Model HTE 01 Thermostat 1 2 3 4 5 Front View Bottom View...

Page 9: ...maintained until the Next schedule period Set point is changed to the scheduled value Mode button is held for 3 seconds displaying Schedule Perm Override To change the temperature units between F and...

Page 10: ...7 Model HTM 01 Base Module Appliance Harness Connector Water Leak Sensor Connector Pairing Button Module Status LED Module Wi Fi Connector remove protective label 1 2 3 4 5 1 2 3 4 5...

Page 11: ...ss the Mode button to change between Thermostat will not generate heating or cooling demands If the equipment supports automatic changeover the thermostat will switch between heating and cooling based...

Page 12: ...or PTAC WSHP HWSHP or FCU while heating or cooling is AUTO If the Thermostat is in Fan Only mode the default fan speed is LO System Type Mode Fan Sequence PTAC Packaged Terminal AC WSHP Water Source H...

Page 13: ...has detected a water leak from the Water Leak Sensor Cable To reset the alarm press all buttons Mode and Fan The thermostat will re check the base modules and if no leaks are detected resume normal o...

Page 14: ...n on Cooling Fan Delay For PTAC WSHP or HWSHP systems in mode the fan will remain running for 1 minute after the cooling demand is satisfied Frost Mode If Emergency Heat is enabled and Frost Protect S...

Page 15: ...conds then release The display shows the number of base modules currently paired Press Mode to scroll back to the Schedule Parameter and use the button to toggle schedule to Y Press Fan to confirm Whe...

Page 16: ...MF or Weekend SS MF Set periods SS Set periods Same schedule throughout the week Set periods Different schedule each day MO TU WE TH FR SA SU Set periods Choose Schedule Type Periods SS WK MO TU WE TH...

Page 17: ...day or group of days can be programmed After the 6th period is programmed the HTE 01 Thermostat will move to the next day or group depending on the schedule type Once all periods and day groups have...

Page 18: ...sed and are recommended on commercial applications Hardwired Installation Battery installation is optional if Thermostat is hardwired R and C terminal connected to 24 volt only power When the battery...

Page 19: ...VAC Battery 3 0 VDC 2 AA batteries Operating Ambient 32 F 122 F 0 C 50 C Operating Humidity 95 Non condensing RH Program 5 2 7 days Dimension 3 93 W x 3 93 H x 1 1 D Frequency ISM Band 915MHZ Model HT...

Page 20: ...Designed and Engineered in New York U S Registered Trademark Patents pending www habitattechnologies com HC UM HTE 01 HTM 01 2020 05 v2 Smarter Control Solutions...

Reviews: