7
LED Status Indication
State
Description
Flashing
Green
Pairing
Base module is seeking to pair with
the thermostat.
Green
Paired
Base module is paired with the thermostat.
Red
Not
Paired
Base module is not paired with a
thermostat.
2 Red
Flashes then
Pause
Alarm
Base module indicating an alarm (Water
Leak, Smoke or CO2) accompanied by
descriptive text on the thermostat display.
Flashing
Red
Identify
Mode
Base module is in identify mode initiated by
the thermostat or web application.
Alternating
Green/Red
Factory
Reset
Hold the PAIR button for 10 seconds and
it begins to flash. Release and press again
briefly to reset.
x
y
Flashing
x
times
Green then
y
times Red
Firmware
Version
Indicates version x.y (eg. 2 green then 7
green = version 2.7.) Press and release PAIR
button within 10 seconds of power up.
n
Flash Red
n
times
Base
Module
Number
Indicates base module number (1-8). Press
and release PAIR button more than 10 sec-
onds after power up.
The following table shows the base module state corresponding to the
LED Status Indication.
LED Status Indication