PC Program Setup - 3624 ProBrix Plus
Operator Manual
ORBISPHERE
There are 3 access levels defined:
• Quality Control Manager
• Supervisor
• Operator
The Quality Control Manager has full access to all menus and options, and is the only
user with access to this
Access Levels
dialog box.
Supervisor level has access to all menus and options apart from this
Access Levels
table.
Operator level has no access to any option in either the File or Configuration menus,
apart from starting and ending a measurement process (see
). In addition operator level has no access to either the
CO2 P/T
or
TRUE
CO2
button, or the
Clear
button in the LINE window.
Note:
Each person on the Access Rights list has access to his or her own personal
ID
, which
can be changed if required.
Initial access to this table is by the default ID
1234
(name Armstrong), which has been
allocated to the QC Manager. This should be changed immediately to a valid ID and
Name.
For each individual, a name, an alphanumeric ID (minimum of 4 characters) and an
access level is required. As mentioned above, only the
QC Manager
level can add,
remove or change existing entries. The list is displayed alphabetically and holds a
maximum of 100 entries.
If the
No ID required
box is checked, then all users are given access to all options and
menus (with the exception of this
Access Level and ID's
option) without being prompted
for a password. Note, however, that all actions will still be logged, but without the user
name.
4.2.2 Setting a LINE Configuration
Line status
shows if the line is open (active) to allow measurements to be taken. If the
line is active, this box is checked. The line is usually started from the Start Line A/B
options (see
“Measurement From the PC” on page 31
Up to two filling lines may be
displayed in the program window.
Each line will be connected to a
separate PC COM port, which will
h ave bee n se t up during the
installation process.
Access the LINE you wish to
configure, by selecting the
Line A
o r
L i n e B
o p t i o n . M o d i f y
p a r a m e t e r s f o r t h a t L I N E b y
selecting the
Change
button.
Fig 4-2:
Line Configuration
Summary of Contents for ORBISPHERE 3624
Page 1: ...Operator Manual ORBISPHERE 3624 Revision F 03 10 2008 ...
Page 2: ......
Page 14: ...8 of 96 Manual Overview 3624 ProBrix Plus Operator Manual ORBISPHERE ...
Page 32: ...26 of 96 Installation 3624 ProBrix Plus Operator Manual ORBISPHERE ...
Page 60: ...54 of 96 PC Program Setup 3624 ProBrix Plus Operator Manual ORBISPHERE ...
Page 68: ...62 of 96 Calibrations 3624 ProBrix Plus Operator Manual ORBISPHERE ...
Page 82: ...76 of 96 Accessories and Attachments 3624 ProBrix Plus Operator Manual ORBISPHERE ...
Page 98: ...92 of 96 Glossary 3624 ProBrix Plus Operator Manual ORBISPHERE ...
Page 101: ...3624 ProBrix Plus User Notes 95 of 96 Operator Manual ORBISPHERE User Notes ...
Page 102: ......