background image

SYSTEM

  Readjust temp.

  Stir

 

  Temperature unit. 

SYSTEM

Temperature unit. 

Celsius

Farenheit

SYSTEM

SYSTEM

SYSTEM

SYSTEM

SYSTEM

SYSTEM

SYSTEM

SYSTEM

  Sample ID

   

  Data output

  Type of report

  Sample ID

   

  Data output

  Type of report

  Sample ID

   

  Data output

  Type of report

  Data output

  Type of report

  Users

  Type of report

  Users

  Header

  Users

  Header

  Identify sensor

SYSTEM

SYSTEM

  Header

  Identify sensor

  Date / Time

  Identify sensor

  Date / Time

  Language

SYSTEM

   ENGLISH

   GERMAN

   SPANISH

   FRENCH

   ITALIAN

SYSTEM

SYSTEM

  Date / Time

  Language

  Display contrast

  Language

  Display contrast

  Readjust temp.

Identify sensor

Sensor data pH

  Model:_

  Serial no.:_

  Exit

Data / Time

04

-06-2007      09:30

Monday

SYSTEM

Codification:

Automatic

Manual

SYSTEM

Data output

Deactivated

For printer

For computer

SYSTEM

Header. Line 1

Maxim. 40 characters

_

SYSTEM

Header. Line 2

Maxim. 40 characters

_

SYSTEM

User 1 

User 2

User 3

SYSTEM

Samples by report:

Several

One sample

SYSTEM

Type of report

Reduced

Standard

GLP

SYSTEM

Users

Yes

No

SYSTEM

Correction 

25.0°C: 0.0 °C

85.0°C: 0.0 °C

SYSTEM

SYSTEM

Display contrast

∆∆∆∆∆∆∆∆∆∆∆∆

Display contrast

∆∆∆∆∆∆∆∆∆∆∆∆∆∆∆

SYSTEM

  Display contrast

  Readjust temp.

 

  Stir

SYSTEM

Stir

Stirrer n. 1 OFF

25%

ON

SYSTEM

Stir

Stirrer n. 1 ON

25%

OFF

10-04-2010     17:15
  

  

  SYSTEM

 

4. Operation

4.12. System

Sample coding:

Automatic

: A consecutive number per each sample .

Manual:

  The  user  introduces  by  an  external  PC  keyboard  a 

specific code per each sample before starting the measurement .

Data  sending:

  Select  “deactivated”  if  there  is  neither  a 

printer nor a connected PC .  If a “printer” or PC is selected the 
following options will appear:

Printer or PC data output, options:

Only with Standard & GLP report

Users

: The name will appear on the 

printed report (17
 characters) .

Report

  header .  Two  lines  of  40 

characters  for  the  company  name, 
etc, that will appear in the printed 
report .

Sensor identification:

 Model and 

serial number of the sensor in use . 
These  data  will  appear  on  the 
printed report .

Temperature readjustment.

 See page 17 .

Stir.

Independent activation of the stirrer .

16

Summary of Contents for sension ph31

Page 1: ...ACH Company 2010 All rights reserved Printed in Spain Manual Manual Manual de instru es Manuel d utilisateur 07 2010 Edition 1 07 2010 Edici n 1 07 2010 Edi o 1 07 2010 Edition 1 2010 7 DOC022 97 9024...

Page 2: ......

Page 3: ...ENGLISH ESPA OL FRAN AIS PORTUGU S CONTACT...

Page 4: ......

Page 5: ...iagram 7 4 5 pH calibration 8 4 6 Other options for calibration 9 4 7 pH measurements 10 4 8 Re programming pH measurement 11 4 9 Printing data of pH measurements 12 4 10 mV measurements 14 4 11 Data...

Page 6: ...5 mV calibration Automatic recognition of redox standard 220 mV at 25 C 77 F Calibration at any mV value Manual introduction of the calibration parameters Temperature readjustment Correction of the te...

Page 7: ...abels Read carefully all labels and tags attached to the instrument Accessories Buffer solutions 135 ml flasks Magnetic stirrer Calibration flasks with magnetic bar inside Electrolyte for the electrod...

Page 8: ...ture 3 Drive the stick into the hole 4 Turn the shift in a counterclockwise until the stick is well fixed Place the o ring at 135 140 mm from the base in order to avoid the shock of the sensor against...

Page 9: ...Make sure the power adapter matches your local power supply 4 1 Description Keys Switch on Switch off Confirms the option displayed When there is more than one option accepts the one marked in negati...

Page 10: ...majority of applications pH Resolution 0 01 pH Isopotential pH 7 00 Measurements By stability with standard criterion In continuous pressing twice the key Calibration in 1 2 or 3 points with technica...

Page 11: ...ution 0 01 Meas By stability Display mV No Limits No Isopotential pH 7 Measurement condit Technical Buffers DIN 19266 Buffers User buffers To a X value Data Introduction Theoretical cal Cal frequency...

Page 12: ...values similar to those of the buffer solution It corrects the asymmetry potential of the electrode Two point calibration This is the most common calibration It is recommended to start with pH 7 as fi...

Page 13: ...C 77 F Buffers DIN 19266 pH 1 679 4 006 6 865 7 000 9 180 10 012 and 12 454 User s buffers Suitable when the two above mentioned options will not be used ThesensION PH31allowsintroducingthetablepH Tem...

Page 14: ...us 10 04 2010 17 15 pH MEASURE New calibration in 1 day 4 Operation 4 7 pH measurements Measurement by stability This is the default measuring mode for the sensION PH31 Meanwhile the reading is in evo...

Page 15: ...limit pH 8 20 Start Measurement by stability 10 04 2010 17 15 pH MEASURE New calibration in 1 day Default programming standard Other options Resolution 0 01 pH 0 1 pH 0 01 pH 0 001 pH Measuring mode...

Page 16: ...ry 24 h SYSTEM SYSTEM Sample ID Data Output Date Time Language Display contrast Sample ID Data Output Date Time Language Display contrast SYSTEM Data output Deactivated For printer For computer SYSTEM...

Page 17: ...50 14T Serial number 7890 pHiso pH 7 pH 7 00 CALIBRATED 14 02 2010 08 50 37 Technical Sens A P T t St Buffers mV C s 4 01 7 00 100 3 0 1 25 6 25 CONDITIONS CHANNEL 1 STABILITY MEASUREMENTS STANDARD C...

Page 18: ...ing Data Data introduction Compensation 000 0 mV Compensation 0 mV Continue Factory Adjust Use standard 220 mV Continue CALIBRATING mV To a X value Use specific standard Continue CALIBRATING mV 10 04...

Page 19: ...ple pH C Time St 15 03 07 14 36 38510 10 15 23 5 00 15 30 15 03 07 14 40 38511 9 85 23 2 00 22 30 15 03 07 14 46 38512 10 23 22 8 00 18 30 16 03 07 08 36 Pozo1 7 48 23 1 00 25 30 pH CALIBRATION DATA C...

Page 20: ...veral One sample SYSTEM Type of report Reduced Standard GLP SYSTEM Users Yes No SYSTEM Correction 25 0 C 0 0 C 85 0 C 0 0 C SYSTEM SYSTEM Display contrast Display contrast SYSTEM Display contrast Read...

Page 21: ...Continue Calibration pH 4 Operation 4 13 Temperature readjustment The sensION PH31 allows the correction of the deviation presented by a temperature probe integrated in the electrode or separated sens...

Page 22: ...temperature compensation in the measurements Example for electrode behavior a Electrode calibration line at room temperature b A calibration line with pHiso 7 to apply when measure at 70 C c Real cal...

Page 23: ...y can be exported to an Excel program as well See PC connection cables at page 20 Replacement parts Data sending to PC ComLabo software ComLabo PN LZW8999 99 ComLabo Software allows control ling from...

Page 24: ...perature Check the electrode MEASURING by stability UNSTABLE READING Time 300 s Check temperature Check the electrode MEASURING by stability pH out of range Check the electrode MEASURING by stability...

Page 25: ...repair or attempted repair not authorized by Hach Company Any product not used in accordance with the instructions furnished by Hach Company Freight charges to return merchandise to Hach Company Freig...