Installation
Seite 34 von 38
QSL-T/QST-150-25/45 V3
Standard
Original operating manual
Rev1.1
4.4
Connection of sensor cable
Assignment of sensor connector
Plug:
Molex Nano-Fit 105308-1210
For the connection to your converter of the HST-Series, we offer suitable adapter cables.
Please contact our sales department (see 8.3 contact information).
HINT
It must be ensured that the speed controller is connected to the temperature sensor of the
motor and reliably protects it from overtemperature.
Mounting of sensor connector
The sensor plug is located inside the motor on the
Q150 V3. To mount the plug, the two aluminum
clamping plates and the cable grommet must first
be dismantled. The sensor cable must now be
inserted through the cable grommet. If this is not
possible, e.g. because a plug is already crimped
on, the cable grommet can also be cut open with
a sharp knife and placed around the sensor cable.
Now the sensor cable can be plugged into the
sensor plug inside the motor and secured with the
two aluminum plates.
Pin
Assignment
Pin
Assignment
1
GND
6
+5V
2
Hall_2
7
Hall_1
3
Hall_3
8
Temp_Sensor 2
(Unassigned by
default)
4
N.C.
9
GND_Temp 2
(Unassigned by
default)
5
Temp_Sensor
10
GND_Temp
Feedthrough for
sensor plug