  The  required  personal  protective  equipment  for  the  operators,  service  and  repair  personnel  is  available 

and is used. 

  The operating instructions are always available at the location where the equipment is used and that they 

are legible and complete. 

  The unit is only operated, serviced and repaired by qualified and authorized personnel. 

  This  personnel  is  regularly  trained  in  all  applicable  matters  regarding  safety  at  work  and  environmental 

protection, and that they are familiar with the operating manual and, in particular, the safety instructions it 
contains. 

  Any safety and warning signs on the devices are not removed and remain legible. 

  customers equipment at site must comply with currently applicable ATEX-regulations 

 

   

WARNING!

 

It is not allowed to make constructive changes of the equipment! 

 

2.3 

Requirements for the operating personnel 

  The units may only be operated by qualified persons that are appropriately trained and that are familiar with 
it. They must have their employer’s authorization for operation of the units. 
Before  starting  work,  the  operating  personnel  must  have  read  the  operating  and  installation  instructions, 
especially the chapter "Safety Instructions". 

This  is  especially  important  for  operating  personnel  that  rarely  uses  the  equipment,  i.e.  for  installation  or 
maintenance work. 

   

DANGER!

 

In order to avoid severe injury, please pay attention to the following when using the equipment: 

  Use protective clothes/equipment. 

  Do not wear long hair hanging down open. 

  Do not wear rings or other jewelry. 

  Do not wear clothes that are too big/wide. 

  Do not reach into ropes, chains, drive parts or other moving parts with your hands 

 

2.4 

Appropriate use 

 

Devices are intended for deflecting a wire rope in all directions. 

 

The permitted safe working load of the devices must not be exceeded! An exception can be made during the 
load test before initial operation, carried out by a licensed qualified person. 

 

 

  Defective  devices  and  load  suspension  devices  must  not  be  used  until  they  have  been  repaired!  Only 

original spare parts must be used. Non-compliance will result in any warranty claims becoming void. 

  Liability and warranty will become void if unauthorized modifications of the units are made by the user! 

 

 

  The permitted environmental temperature during equipment operation is 

–20°C up to +50°C. 

 

 

   

DANGER!

 

The ambient temperature range must not be exceeded! 

 

 

 

 

NOTICE!

 

If the units are not used as intended, safe operation is not guaranteed. 

The  operator  alone  is  responsible  for  all  personal  injury  and  damage  to  property  resulting  from  improper 
use. 

 

2.5 

Basic safety measures 

  Observe installation-, operation- and maintenance instruction. 

  Pay attention to caution notes at units and in the manual. 

  Observe safety distances. 

  Take care for a free view on the load. 

  Only use this devices appropriately. 

Summary of Contents for 108/99

Page 1: ...Rev 01 5 52 624 00 01 01 Pedestal 108 99 108 22 Installation Operating and Maintenance Instructions...

Page 2: ...changes Table of Contents 1 Information 3 2 Safety 3 2 1 Warning notice and symbols 3 2 2 Duty of care of the owner 3 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 4 2 5 Basic sa...

Page 3: ...unpredictable hazards For any resulting damage or personal injury HADEF assumes no liability The unit was designed and built following a risk analysis and careful selection of the harmonized standard...

Page 4: ...r maintenance work DANGER In order to avoid severe injury please pay attention to the following when using the equipment Use protective clothes equipment Do not wear long hair hanging down open Do not...

Page 5: ...ked before delivery Do not throw or drop the accessories Use adequate means of transport Transport and means of transport must be suitable for the local conditions 3 2 Storage Store the accessories at...

Page 6: ...3 7 1000 180 135 13 10 2 2000 240 185 18 23 8 3200 300 230 23 44 5000 360 280 27 75 12500 530 420 38 195 20000 645 510 46 360 108 22 capacity kg rope pulley diameter max rope diameter mm weight outer...

Page 7: ...minimum dimension M from the centre of the drum to the centre of the sheave or from sheave to sheave must be observed Illustration 3 NOTICE Skewed running and non compliance with the minimum distances...

Page 8: ...with more than one motor driven hoist movement i e lifting and trolley movement must be tested by a licensed qualified person before putting in operation An exception is hoists ready for operation ac...

Page 9: ...service every 12 months check screw connections X check wear and tear of rope pulley X check smooth running of rope pulley X check smooth running of rope within pulley X equipment check by a qualified...