12
5.52.270.00.01.04
13.2
Lubricant - Selection
FUCHS
SHELL
ESSO
MOBIL
TOTAL
CASTROL
KLÜBER
Renolit FEP 2
Alvania EP 2
Unirex EP 2
Mobilux EP 2
MULTIS EP2
--
--
Stabylan 5006
--
--
--
--
Optimol Viscoleb 1500
Klüberoil 4UH 1-1500
--
--
--
--
--
--
Wolfracoat 99113
Chain lubricant OKS 451
13.3
Lubricant for food industry – Selection (as option*)
SHELL
MOBIL
CASTROL
KLÜBER
Gearing
FM Grease HD2
Mobilgrease FM 222
--
Klüberoil 4UH 1-1500 N
Load chain
--
Lubricant FM 100
Optimol Viscoleb 1500
--
Load hook;
Pulleys
Gear rim;
Drive pinion
FM Grease HD2
Mobilgrease FM 222
--
--
* must be mentioned by order
14
Trouble
Please pay attention to the following in case of problems:
Troubles with the equipment must only be repaired by qualified personnel.
Secure the unit against unintended operation start.
Put up a warning note indicating that the unit is not to be used.
Secure the working area of moving parts of the unit.
Please read the chapter "Safety instructions".
Notes on the repair of faults are found in the following table.
For the repair of failures please contact our service department.
CAUTION!
Trouble caused by wear or damage to parts such as wire ropes, chains, chain wheels, axes, bearings,
brake parts, etc., must be remedied by replacing the parts with original spare parts.
15
Remedy
Trouble
Cause
Remedy
The load is no longer pulled
Clamping jaws are worn
Replace them by new, original clamping jaws.
The clamping jaws are blocked.
Remove obstacle, check clamping jaws and wire rope for
damage and replace if necessary.
Damage of wire rope
Check the wire rope and replace it by a new special wire
rope if necessary.
Overload caused shearing-off of the safety pin.
Reduce the load, replace the safety pin by a new original
safety pin.
16
Decommissioning
WARNING!
It is essential that the following points are observed in order to prevent damage to the equipment or critical
injury when the device is being decommissioned:
It is mandatory that all steps for decommissioning the machine are carried out in the indicated sequence:
First secure the working area for decommissioning, leaving plenty of space.
Read the chapter "Safety instructions".
Disassembly is carried out in reverse order to the assembly.
Please make sure that all operating material is disposed of in accordance with environmental regulations.