background image

 

 

 

 

5.52.653.01.01.04 

 

 

 

2.3 

Requirements for the operating personnel 

  The units may only be operated by qualified persons that are appropriately trained and that are familiar with 
it. They must have their employer’s authorization for operation of the units. 
Before  starting  work,  the  operating  personnel  must  have  read  the  operating  and  installation  instructions, 
especially the chapter "Safety Instructions". 

This  is  especially  important  for  operating  personnel  that  rarely  uses  the  equipment,  i.e.  for  installation  or 
maintenance work. 

   

DANGER!

 

In order to avoid severe injury, please pay attention to the following when using the equipment: 

  Use protective clothes/equipment. 

  Do not wear long hair hanging down open. 

  Do not wear rings or other jewelry. 

  Do not wear clothes that are too big/wide. 

  Do not reach into ropes, chains, drive parts or other moving parts with your hands 

 

 

2.4 

Appropriate use 

The permitted safe working load of the devices must not be exceeded! An exception can be made during the 
load test before initial operation, carried out by a licensed qualified person. 

 

 

  Defective  devices  and  load  suspension  devices  must  not  be  used  until  they  have  been  repaired!  Only 

original spare parts must be used. Non-compliance will result in any warranty claims becoming void. 

  Liability and warranty will become void if unauthorized modifications of the units are made by the user! 

  The permissible ambient temperature when operating the devices: 

Power unit 

Device classification for 

Not explosive atmosphere 

Explosive atmosphere 

according to  

 ATEX 

)* )**

 

Manual 

-20°C/+50°C 

-20°C/+40°C 

Motor 

-20°C/+40°C 

-20°C/+40°C 

 

) * At an atmospheric pressure range from 0.8bar to 1.1bar and an oxygen content of approx. 21% 

) ** Devices of this category have been specially modified and labeled by the manufacturer

 

   

DANGER!

 

The permissible ambient temperature must not be exceeded! 

 

  Moving horizontally on beams. 

 

 

   

DANGER!

 

The use is not allowed: 

  for pulling loose of stuck loads, dragging of loads and inclined pulling. 

  in explosive atmosphere, except the unit is especially modified for it and marked by an indication label. 

  in reactor containment vessels. 

  to transport people. 

  The device is not suitable for use on stages and in studios. 

Persons must not stand under a suspended load. 

 

 

 

 

NOTICE!

 

If the units are not used appropriately, it is not possible to ensure safe operation. 

The  owner  and  operator  have  sole  liability  for  all  personal  injury  and  damage  to  property  arising  from 
inappropriate use. 

 

 

 

   

DANGER!

 

It’s  only  allowed  to  use  the  unit  in  the  EX-classification  which  is  named  on  the  type  plate; 
or in lower classes 

 

 

Summary of Contents for 19/90

Page 1: ... IIIA T135 C Db II 2G Ex h IIB T3 Gb or II 2D Ex h IIIA T200 C Db DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive dusts It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist at the same time Installation Operating and Maintenance Instructions ...

Page 2: ...able of Contents 1 Information 3 2 Safety 3 2 1 Warning notice and symbols 4 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 5 2 4 Appropriate use 5 2 5 Basic safety measures 6 2 6 Explosion protection 7 3 Transport and Storage 10 3 1 Transport 10 3 2 Safety device for transport 10 3 3 Storage 10 4 Description 10 4 1 Areas of application 10 4 2 Design 10 4 3 Functions ...

Page 3: ...rformance of the devices and meeting any warranty claims require adherence to all instructions in this manual Before delivery all products are packed properly Check the goods after receipt for any damage caused during transport Report any damage immediately to the forwarding agent This manual serves for safe and efficient use of this hoist Illustrations serve to explain something and may differ fr...

Page 4: ...hey must be suitable for use in area prone to explosion The owner is responsible for this However in everyday operation this degree of safety can only be achieved if all measures required are taken It falls within the duty of care of the owner user of the devices to plan these measures and to check that they are being complied with Complete the operating and installation instructions by any instru...

Page 5: ...re parts must be used Non compliance will result in any warranty claims becoming void Liability and warranty will become void if unauthorized modifications of the units are made by the user The permissible ambient temperature when operating the devices Power unit Device classification for Not explosive atmosphere Explosive atmosphere according to ATEX Manual 20 C 50 C 20 C 40 C Motor 20 C 40 C 20 ...

Page 6: ...d must be securely attached to the hook and be seated at the bottom of the hook The safety catch of hooks must be closed When charged the housing may not be in contact somewhere DANGER Special safety measures for use in areas prone to explosion Not to be used with IIC gases and IIB gases hydrogen sulphide ethylene oxide and light metal and shock sensitive dusts No use in temperature class T5 or T6...

Page 7: ...vice category 1 2 3 for use in zone 0 for use in zone 1 for use in zone 2 G EX atmosphere G D caused by gas steam fog caused by dust Ex h type of protection for mechanical devices including e g c construction safety k encapsulation of liquids IIB explosion group IIA IIB IIC limit gap widths MESG 0 9 mm limit gap widths MESG 0 9 0 5 mm limit gap widths MESG 0 5 mm T4 Temperature class gases for dus...

Page 8: ...temperature classes As gas air mixtures for T5 do not occur with normal use and only very rarely occur for T6 for specific gas air mixtures such as carbon disulphide IIC our hoists are not rated for these temperature classes and must not be used for these classes Temperature class Ignition tem perature of gas C max surface temperature of the operating material in C T1 450 450 T2 300 450 300 T3 200...

Page 9: ...5 52 653 01 01 04 9 2 6 4 Explosion hazards recognizing and preventing ...

Page 10: ...osion must be taken out of service 4 Description 4 1 Areas of application The devices must be as far as possible installed in a covered room If they are used in the open protect the units against the effects of weather such as rain hail snow direct sunshine dust etc we recommend to use a cover in parking position If the device is set up in a continuously humid environment with strong temperature f...

Page 11: ...ack end stops by rubber buffers 5 Technical data Weights Type bolt Size 500 kg 1 t 1 5 t 2 t 2 5 t 3 2 t 5 t 6 3 t 19 90 N1 4 1 6 8 7 8 7 8 16 6 16 6 31 5 31 5 N2 4 5 8 5 9 9 9 9 19 9 19 9 39 4 39 22 90 N1 5 4 8 1 9 2 10 9 18 6 18 6 36 36 N2 5 8 9 8 10 3 12 8 21 3 21 3 40 5 40 5 Type bolt Size 7 5 t 10 t 12 5 t 16 t 20 t 25 t 32 t 40 t 50 t 19 90 N1 69 88 N2 71 91 22 90 N1 71 92 220 200 430 500 63...

Page 12: ...he inner side X increases or from the inner to the outer side X decreases Washers 6 and rubber discs depended on type leave a distance for the load hook It is important that the load hangs in the middle under the beam so that the two side plates are equally loaded The suspension eye 9 if existent for bigger load bolts must still be swivelling after it has been secured Tighten the hexagon nut 3 and...

Page 13: ...leys up to 3 2 t 2 3 mm 1 1 5 mm each side bigger and for trolleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam 6 4 Tools 7 Control Only people that are familiar with the operation of the lifting devices and cranes may be entrusted with their operation They must be authorized by the employer for the operation of the equipment The employer must ensure that the ...

Page 14: ...ied person before putting into operation for the first time Hoists of 1000 kg capacity and up or with more than one motor driven hoist movement i e lifting and trolley movement must be tested by a licensed qualified person before putting in operation An exception is hoists ready for operation acc validated national regulations with EU declaration of conformity Definition qualified person former ex...

Page 15: ... are valid for operation under normal conditions and single shift operation In case of severe operating conditions e g frequent operation with full load or special environmental conditions e g heat dust etc the intervals must be shortened correspondingly 12 Inspection 12 1 Periodic checks Independently from the regulations of the individual countries lifting devices must be checked at least yearly...

Page 16: ...vice department CAUTION Trouble caused by wear or damage to parts such as wire ropes chains chain wheels axes bearings brake parts etc must be remedied by replacing the parts with original spare parts 15 Remedy Problem Cause Remedy Trolley runs very slowly or not at all Driving pinion dirty or blocked Clean the driving pinion and lubricate it if necessary exchange worn parts Place the hand chain c...

Reviews: