Description
5.52.541.00.01.01
9
4 Description
Pos: 8.2.1.1 /1_HADEF/4--BESCHREIBUNG/Allgemein/Anwendungsbereiche/1.Anwendungsbereiche - Alle (außer 380) @ 2\mod_1291022296255_52.docx @ 17584 @ @ 1
4.1
Areas of application
The devices must be as far as possible installed in a covered room.
If they are used in the open, protect the units against the effects of weather such as rain, hail, snow, direct
sunshine, dust, etc. - we recommend to use a cover in parking position. If the device is set up in a
continuously humid environment with strong temperature fluctuations, the correct functionings are
endangered by the forming of condensation.
Ambient temperature: - 20°C up to + 40°C. Humidity: 100 % or less but not under water
Pos: 8.2.1.2 /1_HADEF/4--BESCHREIBUNG/Allgemein/Anwendungsbereiche/2.Zusatz E+P @ 0\mod_1172067316174_52.docx @ 232 @ @ 1
During longer periods of standstill, corrosion may reduce the function of the brake.
Pos: 8.2.1.3 /1_HADEF/---ALLGEMEIN/Hinweise/EX-Schutz/GEFAHR - Einsatz Geräte Standard/EX @ 1\mod_1190281459161_52.docx @ 7911 @ @ 1
DANGER!
HADEF hoists, in their standard version, are not approved for use in areas that are prone to
explosion.
HADEF supplies special explosion-proof equipment for this purpose which has special EX-name
plates on it stating the EX-classification.
Pos: 8.3.1 /1_HADEF/4--BESCHREIBUNG/Kettenzug/Aufbau/70/06 @ 2\mod_1286524246017_52.docx @ 15970 @ @ 1
4.2 Design
HADEF pneumatic chain hoists are equipped with a suspension eye for stationary use. The one and two
chain fall devices may optionally be equipped with a suspension hook.
All devices can also be supplied with monorail trolley with push travel, hand geared or electric drive.
Type 70/06 APS, stationary
Type 70/06 APR, with push travel trolley
Type 70/06 APH, with geared travel trolley
Type 70/06 APP, with pneumatic trolley
Pos: 8.3.2.1 /1_HADEF/4--BESCHREIBUNG/Kettenzug/Funktionsbeschreibung/Funktionsbeschreibung - Alle P @ 1\mod_1190282950314_52.docx @ 7934 @ @ 1