Inspection
16
5.52.210.00.01.01
11 Inspection
Pos: 16.2 /13-PRÜFUNG/Wiederkehrende Prüfung/01.Wiederkehrende Prüfung @ 0\mod_1175675257580_52.doc @ 3164 @ @ 1
11.1 Periodic
checks
Independently from the regulations of the individual countries, HADEF lifting devices must be checked at
least yearly by a qualified person or licensed qualified person regarding its functional safety.
In Germany it is necessary to observe the accident prevention regulations BGV D6, BGV D8, BGR 500 as
well as DIN 15020 (Basics for cable drives). In other countries, the above mentioned tests and the national
safety regulations apply.
Pos: 16.3.1 /13-PRÜFUNG/Winde+Seilzug/01.Tabelle-Inspektionsintervalle - 7355 @ 1\mod_1266825976021_52.doc @ 12699 @ @ 1
11.2 Inspection
intervals
on commissioning
daily checks
1st service after 3
months
inspection, service
every 3 months
inspection,
service every 12
months
Inspection of the equipment by a qualified person (periodic
inspection)
X
Check screw connections
X
X
Check brake function
X
X
check brake air gap (only for electric devices)
X
check overload protection if existent
X
clean and lubricate the wire rope
X
X
X
check wire rope and wire rope end fastenings for damage
and wear
X
check the load tackle and load hook for cracks and
deformation
X
Pos: 17.1 /14-WARTUNG/*Ü1*/#. Kapitel - Wartung @ 0\mod_1172647693186_52.doc @ 409 @ @ 1