Inspection
20
5.52.800.00.01.00
12 Inspection
Pos: 16.2 /1_HADEF/13-PRÜFUNG/Wiederkehrende Prüfung/01.Wiederkehrende Prüfung @ 0\mod_1175675257580_52.docx @ 3164 @ @ 1
12.1 Periodic
checks
Independently from the regulations of the individual countries, lifting devices must be checked at least yearly
by a qualified person or licensed qualified person regarding its functional safety.
In Germany it is necessary to observe the accident prevention regulations BGV D6, BGV D8, BGR 500 as
well as DIN 15020 (Basics for cable drives). In other countries, the above mentioned tests and the national
safety regulations apply.
Pos: 16.3 /1_HADEF/13-PRÜFUNG/Krane/800/Prüfungsintervalle @ 3\mod_1373889787209_52.docx @ 27077 @ @ 1
12.2 Inspection
intervals
during
putting into
operation
daily
checks
Inspection
every
12 months
check screw connections
X
X
check wheels for wear
X
check function of the wheel brake
X
X
X
inspection of the equipment by an expert
(periodic inspection)
X