Fix the brackets (Optional):
Right
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney
using either a flexible or rigid pipe ɸ 150 or ɸ 120 mm, the choice of
which is left to the installer.
If to install a ɸ 120 mm air exhaust connection, insert the reducer
flange
3
on the hood body outlet.
Fix the pipe
4
in position using sufficient pipe clamps (not
supplied).
Remove the charcoal filters.
Wrong
Drill holes at the marked points with a ɸ10 mm drill bit.
Insert the Wall Plugs 11 into the holes.
Screw 2 screws
10
(5 x 50) to Wall Plugs
11
at the horizontal line
A
; the four fifth length of the
screws
10
(5 x 50) was screwed into the Wall Plugs
11.
Fix a Chimney fixing bracket
21
with 2 screws
10
(5 x 50) at the horizontal line
B
.
Hook the hood body to the 2 screws
10
(5 x 50) at the horizontal line
A
.
Level the hood body itself.
Remove the filter from the inside of the hood body, fix the screws
10
to Wall Plugs
11
at the
points (3).
CONNECTIONS
Attaching
the hood body