Safety Instructions
or other burnable liquids, there is always the danger
of fire or explosion hazards. Never refill the tank di-
rectly over the unit to avoid in case you accidently
spill water, this will flow into the unit.
If spray liquid enters the suction hose, dry the
handpiece so that the suction hose is at the
bottom. Pull the suction hose off the control unit.
Now place the handpiece below the control unit so
that the liquid can drain away without getting into the
handpiece. If necessary, replace a wet dust filter.
The unit must be used again only when the liq-
uid has completely evaporated. If the error occurs
repeatedly, the unit must not be operated and must
be repaired by a specialist.
Change the spray liquid every day. Always add
disinfection additive to the distilled water.
Make certain to observe the instructions of the man-
ufacturer. Rinse the tank daily and fill it with fresh
spray liquid every day.
Empty the unit if it is not in use for a longer pe-
riod of time (e.g. before vacations). Clean out
the tank. Set the spray function on maximum. Now
start the spray function, and the spray liquid will
spray for approx. 3 min. The fluid will be blown out
of the complete spray system and handpiece.