background image

 

 

10 

Getting to know the unit 

 

1  Display of speed and battery charge 
2  LED: ON during reverse rotation 
3  Increase the speed (up) 
4  Decrease the speed (down) 
5  Change direction of rotation 
6  Switching the unit ON/OFF 
7  Warning LED if battery charge is too low 
8  Transport safety switch 

 

                           

1            
2        
3  
4  

               



7

 

 

Summary of Contents for Xantos-BT

Page 1: ...Manual Battery Drill Xantos BT Art No 0842 FB 04 238 Rev 3 Art no 0842 ...

Page 2: ...stallation 11 Before the first use 11 Maintenance Care 12 Accumulators 12 Accumulator running time 12 Charging display 12 Charging process 12 Warning LED 12 Warning signal acoustic 12 Changing the accumulators 13 Clamping the bur tool 13 Adjusting the speed 13 Cleaning the chuck 14 Handling details 15 Troubleshooting 16 Technical data 18 ...

Page 3: ...air slits are not blocked and the extracted air can escape well Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely in your hand Prevent any liquids from entering into the control unit since this could damage the electronic elements Clean the outside of the box only with a damped cloth Make sure that you have unplugged the unit before Check the m...

Page 4: ...ce during the operation To prevent injury work with extreme caution on the foot of the patient and use only light pressure To ensure that the bur tool sits firmly in the chuck do not work with tools which have an oily shaft are worn are bent This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and ...

Page 5: ...y reasons do not change the tool while the motor is running Switch off the unit immediately if the bur comes off during the treatment itself the motor blocks during the treatment Never use the power supply unit Meanwell GS40A12 P1J if it is open if the mains cable socket is damaged or if it has a damaged housing Warning Electric shock may occur Only work with recharging units recommended by hadewe...

Page 6: ...the socket since some components are under electric voltage Any unauthorized or improper handling e g trying to repair the unit of the equipment will immediately nullify the guarantee warranty and any other liabilities of the manufacturer To prevent any possible safety risks make sure you always use only original hadewe accumulators Never disassemble the accumulators in any way In case the unit wa...

Page 7: ... electricity vessel If you have to move the unit with damaged accumulators you have to remove the accumulators first see page 10 A damaged accumu lator may never be shipped It is only to be transported in a ireproof non conducting container and under supervision With a damaged accumulator it is possible that battery acid is leaking out Therefore make sure to only touch it wearing protective gloves...

Page 8: ...ivation of the unit during transport Unintentional activation of the unit during transport can block the hand piece and might lead to overheating burning of the unit Also make sure to follow any local or national regulations regarding the transport itself and the labeling of the transport package A mechanically damaged unit or a unit with damaged packaging is not allowed to be shipped or transport...

Page 9: ... capper etc first Then handle the cleaning of the tool according to the instructions of it s manufacturer Remove tissue remains by wiping off the unit with a mildly moistened paper cloth Afterwards clean all surfaces with disinfection cloth e g Mikrozid AF Tücher of Schülke and Mayr The charging unit is only to be cleaned with a dry cloth ...

Page 10: ...d and battery charge 2 LED ON during reverse rotation 3 Increase the speed up 4 Decrease the speed down 5 Change direction of rotation 6 Switching the unit ON OFF 7 Warning LED if battery charge is too low 8 Transport safety switch 1 2 3 4 5 6 7 8 ...

Page 11: ... Dental technique laboratory Milling trimming and polishing work at plaster casts and models Do not use this unit for dentist purposes i e working directly on the patient Industry Grinding milling and polishing works Installation site location The installation of the workroom must correspond to any regulations according to your country laws Set up the control unit so that the ventilation slits are...

Page 12: ... on how to proceed Before first use Before the first start you have to turn the main switch from 0 to 1 with a coin or a screwdriver Because of safety reasons you have to turn the transport safety switch from 1 to 0 for longer transportations and shipment This switch interrupts the accu from the control unit ...

Page 13: ... During the charging operation you will see a moving line in the display Once the accumulators are fully charged the display will show the word FULL If the accumulators are empty the charging time should take approx 2 hours Working with the unit is possible during the charging process but the charging of the unit will take longer time then Should the unit be completely empty the accumulators will ...

Page 14: ...lamping the tool bur The handpiece is equipped with a chuck which can hold all burs with a diameter of 2 35 mm this is the diameter usually used for tools in podiatry To open the chuck push the spanner forward with your thumb and leave it there Now insert the tool as far as possible Pull back the knob and the tool will be firmly clamped For security reasons only change the tool if the handpiece is...

Page 15: ...k To assemble the chuck follow the steps in reverse order Make sure that the chuck is opened during the assembly the handpiece button must be in forward position and is firmly applied afterwards Cleaning the chuck Soak the chuck in spirit or a special cleaning liquid for tools Clean the slits and the hole of the chuck with a dry scrubber or brush Rinse the chuck very well and make sure you let it ...

Page 16: ...the handpiece in form of rust bloom and causes pitting Therefore when you not working with the handpiece always remove the bur tool from it Always make sure that you do not let the handpiece fall down or exposes it to any shocks The ball bearings and the motor could be damaged by this Only work with tools which are flawless Do not work with tools which are bent or out of balance whose shaft is wor...

Page 17: ...an the chuck according to the instructions in the manual The unit has no function at all Press the reset switch located under the unit The unit should now be fully functional again If a fuse is blown let the fuse be exchanged by a professional service point following these instructions The plug has to be removed from the connected charging unit Switch the unit off and make sure that the handpiece ...

Page 18: ...illisecond to check the voltage and initiate the warning signal in case of a deep discharge accumulators being completely empty being imminent This switching on is accompanied by a silent clicking noise from the transistor ...

Page 19: ...tandards or normative documents 2014 30 EU directive EMC 2011 65 EU ROHS DIN EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements hadewe GmbH Grambartstraße 10 30165 Hannover Germany Symbols Caution Important Note Follow instructions for use I O Unit ON OFF Speed Regulation Up Down Switch to reverse direction LED ON LED is on in reverse direction Direct current...

Page 20: ...hadewe GmbH Grambartstraße 10 30165 Hannover Germany info hadewe de www hadewe de ...

Reviews: