20
OPERATION MANUAL
F
ig
. 5.4
6. Release the tension off the blade by turning the tension
handle clockwise until the blade is loose. (Fig.5.4)
7. Remove the old blade and replace the new blade
making sure that the teeth are facing in th right direc-
tion.
NOTE:
Always wear leather gloves when handling cutting
blades. The blades are very sharp and could cause injury to
hands.
8. Re-tension the blade and replace the back cover.
9. Replace the blade guard on the movable roller guide making sure that the blade runs freely
with out touching the guards.
10. Adjust the movable blade guide so that it just clears the work piece.
11. Switch the machine on and make sure the blade is running correctly
5.3 CHANGING THE COOLANT
F
ig
. 5.5
This band saw is fitted with a coolant system that extends
the life of the band saw blade by lowering the temperature
of the blade and the workpiece.
To maintain the effectiveness of the cutting it is important
to keep the coolant clean, therefore the coolant should be
changed every 1000 hrs.
To change the coolant.
1. DISCONNECT THE MACHINE FROM THE POWER SUPPLY
2. Place a container under the drain and remove the
drain plug on the side of the machine. (Fig 5.5)
3. Once the coolant is empty remove the two screws that
secure the screen on the top of the reservoir, and
remove the screen. (Fig.5.6)
4. With clean rags, wipe out the bottom of the coolant
reservoir until it is clean and free from dirt or metal
chips.
5. Replace the screen and drain plug and refile with clean
coolant.
F
ig
. 5.6
Page 20
Instruction Manual for EB-260V (B062V)
04/04/2019