background image

17

You are able to see errors and operating errors in the status messages of the LED display and then correct 
them accordingly.
Reset should be carried out in the case that other non-defined conditions arise and the lock does not operate 
flawlessly even though the battery has been replaced. This resets the lock to factory default settings and all 
programming is deleted.  You can obtain the instructions for this via the address or telephone number stated 
on page 2. 

Replacing the battery

 

1. Loosen the screw on the side of the cover using a TG 6

 

 screwdriver.

 

2. Open the battery compartment and remove the battery pack.

 

Disconnect the two-pole plug-in connector from the battery pack.

 

3. Connect the new battery pack to the plug-in connector and  

 

 

insert the battery into the housing.

 
 

4. Close the battery compartment and screw down.

Codes are not deleted when a battery is replaced.

  

Notice: Please dispose the empty battery pack properly in accordance with the valid

 

environmental regulations!

Battery monitoring / battery alarm

Automatic battery monitoring on the SAFE-O-TRONIC®-LS 100 ensures that a SAFE-O-TRONIC®-LS 100 
with inadequate battery voltage can no longer be operated.

There is an advance warning when all the LEDs flash twice. In this case it is recommended to replace the
battery.

An alarm is triggered after a while if the battery is not replaced.  This is indicated when the red and green 
LEDs light up in turn three times. The battery must now be replaced. In this instance the compartment can 
only be opened but no longer locked.

The lock must only be operated using batteries approved by Häfele. The use of non-approved batteries can 
lead to malfunctions and lock damage.

Maintenance and care

The SAFE-O-TRONIC® LS 100 is maintenance-free. In no case should the lock be oiled or greased with 
lubricants containing mineral oil. 

Only use non-stick, residue-free cleaning agents and disinfectants for cleaning purposes. Do not use any 
heavy cleaning agents, acids or lyes when caring for the product. Also do not use a pressure cleaner. It is also 
not recommended to spray-wash the locks, for example using a hose.
 

Troubleshooting / Operating Errors

Summary of Contents for 231.98.000

Page 1: ...SAFE O TRONIC access Item No 231 98 000 001 002 003 MountingInstructions Dimensions in mm Inches are approximate Electronic Identification and Locking System SAFE O TRONIC LS Cabinet Lock Manual LS 100 ...

Page 2: ...lease observe this important information Handling instructions These mark a work step during user input SAFE O TRONIC is a registered trademark of Schulte Schlagbaum AG Safety and warning notes Please read before initial operation This manual describes the initial operation and operation of a SAFE O TRONIC LS 100 The equipment must only be used for the purpose intended by the manufacturer Please k...

Page 3: ...ad 9 UserCode 9 MasterCode1 9 MasterCode2 9 Codeoverview 9 Operation 10 Function control 10 Initial operation 11 Programming MasterCode2 11 Locking and opening using MasterCode2 12 Locking and opening using the UserCode 12 Further functions 13 Altering MasterCode2 13 Programming MasterCode1 14 OpeningusingMasterCode1 15 Release using MasterCode2 15 Further information 16 LEDdisplay 16 Troubleshoot...

Page 4: ... Exchangeable plate Rotary knob OK key Finish of Code entry Abort key Code entries or programming operations can be rejected by pressing the abort key Keys 1 2 3 4 5 6 7 8 9 0 Number keys for Code entry X 2 1 3 5 7 9 4 6 8 0 Control Elements ...

Page 5: ...cam A cropped or hook shaped locking lever can also be used depending on the properties and condition of the cabinet 5 Fastening bolt for locking lever 6 Bushing for fastening the lock to the door for door thickness from 10 mm to 18 mm 7 Bushing for fastening the lock to the door for door thickness from 1 mm to 9 mm 8 Screw for fastening the lock to the door 9 Rotary knob ...

Page 6: ...to the two holes 19 1 mm 16 mm and 7 mm 2 Fasten the lock 1 using the nut 2 3 Screw on the lock 1 using the screw 8 and the bushing 6 or 7 depending on the thickness of the door 4 Fasten the grommet 3 for setting the rotational direction and the locking cam 4 using the bolt 5 5 Test the lock function by means of the TestCode when the door is open 6 Test the function when the door is closed Replace...

Page 7: ...ng 2 Grommet that is attached to the lock on the inside of the door The opening marked L points downwards 3 Rear side of the lock to which the grommet is attached If the lock is installed in a position whereby the rotary knob is not at the top e g horizontal installation the grommet must be turned accordingly If the rotary knob is to be turned to the right for locking the grommet must be attached ...

Page 8: ... the plate e g for numbers logo etc After inserting a small screwdriver into the center of the plate the old plate is levered out of the lock A new plate can then be snapped in Notice The old plate is destroyed when the plate is replaced ...

Page 9: ... only aware of the MasterCode1 they are protected against suspicion in cases of hidden thefts It means if there is a theft and the compartment has been locked again the employees cannot come into question as offenders Notice MasterCode1 cannot be programmed with 0 as the first number MasterCode2 MasterCode2 can be used by the operator of the facility at any time to open and close the compartment o...

Page 10: ...isabled for one minute as protection against manipulation The lock is blocked after 100 incorrect entries Blocking can only be released with MasterCode2 All locks in the SAFE O TRONIC LS 100 series are delivered with the same factory setting The TestCode for locking and opening is activated in the factory setting TestCode The TestCode can be used to carry out a simple SAFE O TRONIC LS 100 function...

Page 11: ...ogrammed MasterCode2 Programming MasterCode2 Press the OK and abort keys simultaneously and Enter new MasterCode2 Notice 3 5 1 9 7 is only an example code Press the OK key Enter new MasterCode2 one more time Press the OK key Please note The programming procedure will be terminated automatically if a key is not pressed within approx 3 seconds Initial Operation 1 1 3 3 5 5 7 7 9 9 X ...

Page 12: ...erCode2 Notice 3 5 1 9 7 is only an example code Then press the OK key Turn the knob Locking and opening using the UserCode The user has the possibility to enter a random 4 digit UserCode and lock and open the locker Enter the UserCode Notice A four digit code must be entered 9 0 6 0 is only an example code Then press the OK key Turn the knob Initial Operation 1 3 5 7 9 9 6 0 0 ...

Page 13: ...Code2 Notice 3 5 1 9 7 is only an example code Press the OK key Press 2 2 for MasterCode2 Press the OK key Enter new MasterCode2 Notice 4 8 2 7 3 is only an example code Press the OK key Enter new MasterCode2 one more time Press the OK key 1 3 5 7 9 Further Functions 2 X 2 3 7 4 8 2 3 7 4 8 ...

Page 14: ...not permitted Press the OK and abort keys simultaneously and Enter active MasterCode2 Notice 3 5 1 9 7 is only an example code Press the OK key Press 1 1 for MasterCode1 Press the OK key Enter new MasterCode1 Notice 9 0 6 0 9 is only an example code Press the OK key Enter new MasterCode1 one more time Press the OK key Further Functions 9 9 9 9 6 6 X 0 0 0 0 1 3 5 7 9 2 ...

Page 15: ...hat is fitted with a SAFE O TRONIC LS 100 is opened using MasterCode1 it stays blocked for the entry of a UserCode The SAFE O TRONIC LS 100 then has to be released again using MasterCode2 Enter active MasterCode2 Notice 3 5 1 9 7 is only an example code Press the OK key The blocked SAFE O TRONIC LS 100 is now released again for further operation Further Functions 9 9 6 0 0 1 3 5 7 9 ...

Page 16: ...rror the rotary knob was not operated within the released period Alternate Waiting for rotary knob to be operated 1 second Lock has been locked programming successful 2 seconds Lock has been unlocked 1 2 second Code accepted 3 seconds Internal malfunction lock may have to be replaced Red LEDs light up first then the green LEDs for 1 2 a second in each case Blocking triggered by MasterCode 1 cancel...

Page 17: ...ntal regulations Battery monitoring battery alarm Automatic battery monitoring on the SAFE O TRONIC LS 100 ensures that a SAFE O TRONIC LS 100 with inadequate battery voltage can no longer be operated There is an advance warning when all the LEDs flash twice In this case it is recommended to replace the battery An alarm is triggered after a while if the battery is not replaced This is indicated wh...

Page 18: ...10 C to 65 C 14 F to 149 F Storage 25 C to 65 C 13 F to 149 F Relative humidity 10 90 non condensing Protection class according To DIN EN 60529 IP 43 Weight approx 300 g 10 1 2 oz Housing dimensions incl Rotary knob H x W x D 151 mm x 38 mm x 33 mm 5 15 16 x 1 1 2 x 1 5 16 Color of housing frame Similar to RAL 9006 white aluminum Color of the control panel Black Door thickness 1 to 19 mm Technical...

Page 19: ...le NC 27263 1 800 423 3531 www hafele com Further Functions Notice Depending on the printer there can be dimensional deviations when printing this drilling template Therefore please re measure the drilling template before use Technical Data ...

Reviews: