background image

 

 

 

Mounting instructions 

 

 

engl.

 

29

 

Setting into Operation 

Allocate programming and deletion key sticks 

Programming and deletion key sticks are allocated in stand alone mode 
during first commissioning. 
This can be implemented only after supply voltage is fed to the CL 
terminal. 
The locking mode of the CL terminal is pre-set, such that the 
connected CL terminals are unlocked for approx. 5 seconds when an 
authorized electronic key is placed in front of them. Other locking 
modes can be programmed, too (e. g. alternating unlocking/locking 
when placing an authorized key in front of them). The locking mode can 
be modified via special transponder only before programming and 
deletion keys are allocated. Please contact your Dialock sales office for 
this purpose.  

 

Prevent misuse by unauthorized persons! 

Õ 

Keep programming and deletion keys safe, as they might be used to 
allocate or withdraw locking authorisations to or from an electronic 
key. 

 

1.  Keep the green programming and the red deletion key sticks at 

hand. 

2.  If voltage is fed to the CL terminal already, disconnect the voltage 

supply. 

3.  Connect it to the voltage supply again. 

The green LED flashes for a few seconds. 

4.  Place the green programming key stick in front of the reading 

module while the green LED flashes. 
The red LED starts flashing for a short time to confirm that the 
learning procedure has been successful. 

5.  Place the red deletion key stick in front of the reader module, while 

the red LED flashes. 
The red LED is illuminated. 

If errors have occurred during the allocation procedure, proceed as 
follows: 

 

Õ 

Disconnect the voltage supply feed and connect it again. 

Summary of Contents for dialock CL

Page 1: ...ZV Terminal Montageanleitung Mounting instructions Instructions de montage Instrucciones de instalación Istruzioni di montaggio CL terminal Terminal VC Terminale ZV Terminal de CC ...

Page 2: ... items Reader module l an approx 2 5 m long round flat section cable including connector for connection to the control electronics module l Front foil to stick onto the reader module l Spacer plate for surface installation of the reader module Control electronics module l Screwed connections for the control electronics module casing l Screwed PG 9 connections to connect the flat section cable to t...

Page 3: ...8 lock cases and to control them separately Please contact yourDialock sales office if a different operation mode shall be chosen CL terminal Technical Data Power supply 12 VAC Continuous current consumption 200 mA System of protection Reader module IP 54 Control electronics module IP 66 Operation temperature range Reader module 0 60 C Control electronics module 0 60 C Relative air humidity 0 95 O...

Page 4: ...L lock cases 6 Output extender 7 Control electronics module 8 Power supply for control electronics module 9 Power feed cable 10 Interface line RS 232 optional When planning the following construction measures have to be taken in consideration l Exact place provided for the installation of the modules and position of the elements to be switched and controlled l Surface installation or flush fitted ...

Page 5: ...llation drill a hole of 25 mm diameter with a minimum depth of 48 mm for the PG 9 screw fixing 1 2 3 min 48 4 5 min 25 1 2 3 min 60 4 70 Flush fitted installation left hand and surface installation right hand of the reader module 1 Protecting tube min internal diameter 12 mm 2 Cable diameter 8 to 9 mm length 2 5 m 3 Flush fitted box drill hole for the PG 9 screw fixing connection resp 4 Reader mod...

Page 6: ...acer plate and reader module do correspond and the screw heads do not project above the countersinking 4 For installation on metal ÕProvide four drill holes for M4 threads ÕCut the threads ÕFasten the reader module using four countersunk head screws Make sure the 10 mm drill hole in the wall and the fixing holes provided for this purpose in both spacer plate and reader module do correspond and the...

Page 7: ...move it from the cable ÕLead the free cable end through the hole to the control electronics module ÕShorten the cable accordingly ÕFit the screwed G 9 connection to the cable again ÕIntroduce the flat section cable through the opening in the spare connector in such a manner that the arrow imprinted on the plug is on the same side as the red marking on the flat section cable polarity ÕClose the spa...

Page 8: ...ovided 1 2 3 4 3 4 2 5 1 Flush fitted installation left hand and surface installation right hand of the control electronics module 1 Protecting tube min 12 mm inside diameter 2 Cable diameter 8 to 9 mm length 2 5 m 3 Control electronics module 4 Power supply connection 5 Inspection flap Õ To fasten the control electronics module on the wall drill four holes into the wall and insert 6 mm plugs into...

Page 9: ... to the preceding output extender resp 4 Power feed cable for connection with transformer 5 Power supply for the next output extender 1 Screw the output extender down using four screws ø 2 5 mm 2 Plug the connector of the CL lock case into output 1 8 of the output extender If necessary use an extension cable 3 Plug the Western plug of the data line cascade cable that leads to the control electroni...

Page 10: ... the control electronics module 1 On board control electronics module 2 Female Western plug connection for cascading cable 3 Connection for CL display 4 Connection for flat section cable leading to the reader module pin contact strip 5 Supply voltage 6 Serial RS 232 interface to the PC or to the online adapter ...

Page 11: ... CL lock cases 7 Additional CL lock cases up to 8 per output extender 8 Output extender with open collector outputs 9 External CL display optional Mortal danger due to high current stroke ÕMake sure the electrical installation is carried out by experts only 1 Deactivate the fuses of all consumers including CL terminal power supply 2 Make sure all lines are voltage free 3 Drill the necessary holes ...

Page 12: ...e care of the position of the two display connectors ÕAttach the display connector in such a manner that both idle connector contacts point to the inside 6 Shorten the cable 7 Slip the screwed G 9 connections onto the cables to be connected 8 Screw the casing of the control electronics module on the wall using four 4 x 50 mm wood screws 9 Lead the cables through the holes in the casing provided fo...

Page 13: ...tool 2 Contact terminal 11 Open the contact terminals using the connecting tool 12 Put the cables into the contact holes 13 Remove the connecting tool 14 Put the reader head cable into the pin contact strip 15 Put the data line cascading cable into the female Western plug 16 Use the plastic screws supplied to fix the cover on the casing 17 If the control electronics module is flush mounted fit the...

Page 14: ...t your Dialock sales office for this purpose Prevent misuse by unauthorized persons ÕKeep programming and deletion keys safe as they might be used to allocate or withdraw locking authorisations to or from an electronic key 1 Keep the green programming and the red deletion key sticks at hand 2 If voltage is fed to the CL terminal already disconnect the voltage supply 3 Connect it to the voltage sup...

Page 15: ...tempt has failed if the red LED lights up ÕRepeat the allocation of locking authorizations 4 Learn further electronic keys as long as the green LED flashes Activation of further locking units Generally locking authorizations can be allocated to max 128 locking units Within the scope of the Basic Solution however we recommend to connect no more than 8 locking units as this type of allocation of loc...

Page 16: ...zations allocated to the key these must be allocated again for all locking units the key shall be further authorized to 1 Place the red deletion key stick in front of the reader module The red LED flashes 2 Place the electronic key to be deleted in front of the reader module The red LED lights up for a short period The allocated locking authorizations are withdrawn Withdrawal of the locking author...

Page 17: ... red LED extinguishes All locking units to which the electronic key is authorized will be unlocked for approx 5 seconds If the LEDs do not switch over from red to green ÕPlace the electronic key slightly closer to the CL terminal If the LEDs again do not switch over from red to green This electronic key has no locking authorization ÕPlace the authorized electronic key in front of the reader module...

Page 18: ...x erreurs et fautes pouvant résulter de l impression de ces instructions de montage Tous les droits de possibilités de livraison et de modifications techniques sont réservés Version du 02 01 Istruzioni di montaggio 732 29 110 E vietata la copia delle istruzioni di montaggio anche soltanto parziale oppure delle raffigurazioni e dei disegni come anche la riproduzione del layout E esclusa qualsiasi r...

Reviews: