Dialock Cylinder DC - Status: 09.2003 - 732.29.140
Withdrawing rights to all user keys
Should a user key be mislaid and no longer have locking rights, it is nec-
essary to cancel all user keys. Locking rights must then be re-assigned to
the remaining authorised user keys. Refer to the section "Assigning rights
to user key".
1. Press the white button on the panel.
The red LED lights up.
2. Hold the red cancelling key in front of the panel.
The red LED flashes.
3. Hold the green programming key in front of the panel. The red LED
lights up for a moment. All locking rights have now been withdrawn.
Operation
1. Press the white button on the panel.
The red LED lights up.
2. Hold the user key in front of the panel.
3. The Dialock DC Cylinder can be opened within 3 secs. Turn the outer
knob to open the lock.
If the LEDs do not switch from red to green: => hold the user key closer
to the Dialock DC Cylinder. If the LEDs still do not switch from red to
green: => user key has no authorisation.
Important:
The cylinder does not lock automatically. The door has to be locked
manually from the inside or the outside.