31
Mounting and Brief Operating Instructions
E
n
g
lis
h
Dialock Cylinder DC - Status: 09.2003 - 732.29.140
RESET
Note: It is only possible to execute RESET from inside.
1. Unscrew the two grub screws (7) and pull off the inner knob (10).
2. Using metal tweezers or the reset tool, bridge pins 1 and 2. The
RESET process is described below.
3. Following the reset, replace the inner knob (10) and screw it into place
with the three grub screws (7).
RESET process:
When the reset contact points (A) are bridged and the Dialock DC Cylin-
der is switched on, both the LEDs in the panel light up.
After 1 second, the red LED starts to flash. It goes off altogether after
another 3 secs.
Total RESET (long RESET):
If the bridge is closed for more than 4 secs. a total reset is carried out. All
configuration data are returned to their basic settings and all data (includ-
ing user data) are cancelled.
- Release the bridge
after
the red LED has stopped flashing.
Simple RESET (short RESET):
If the bridge is closed for more than 1 sec. but less than 4 secs. a simple
reset is carried out. Only the project code is reset.
- Release the bridge
before
red LED stops flashing.