Dialock Door Terminals DTSH, DTSH FH - Status: 07.2008 - 732.29.134
65
English
Installation Instructions
Short instructions
Allocate locking authorisations to user key
Present green programming key to the control panel.
1.
ð
Blue LED flashes.
Present user key that has to be trained to the control panel for 5 sec-
2.
onds. The locking authorisations for the user key have been allocated
when the blue LED flashes briefly.
Remove trained user key.
3.
Present the next user key to be trained to the control panel within
4.
5 seconds.
Withdraw locking authorisations from user key
Present red clearing key to the control panel.
1.
ð
Red LED flashes.
Present user key that has to be cleared to the control panel. When
2.
the red LED flashes briefly, the locking authorisations have been with-
drawn. The Dialock DTSH door terminal then goes into normal operat-
ing mode.
If no more keys are presented to the control panel the DTSH goes
into the normal operating mode.
Withdraw locking authorisations from all user keys
If a user key has been lost and you wish to cancel its locking authorisa-
tions, all user keys must first be deleted at the Dialock DTSH door termi-
nal. Access rights must then be re-allocated to all user keys with locking
authorisations.
Present red clearing key to the control panel.
1.
ð
Red LED flashes.
Present green programming key to the control panel.
2.
ð
Red LED flashes briefly.
Re-allocate access rights to all user keys that are still to have locking
3.
authorisations.