background image

19

Maintenance of the remote control

Cleaning the remote control:  

Clean the remote control with a damp cloth and a neutral 
solution of detergent without abrasive substances. 

Changing the battery:   

• 

Open the battery casing. 

• 

Replace the flat batteries with 3 new 1.5 V type AAA 
batteries. 

 

Respect the polarity indicated in the battery casing when 
inserting the new battery! 

• 

Close the battery casing up again.  

Disposal of the batteries 

Ultimate disposal of the batteries should be handled according 
to all national laws and regulations. Do not place used 
batteries in your regular waste. 
Ultimate disposal of the batteries must be done safely

.

Contact your local waste management officials for other 
information regarding the environmentally sound collection, 
recycling, and disposal of the batteries. 

Operation anomalies

The hood does not work

Make sure that: 
• 

There is no current blackout 

• 

A speed has been effectively selected. 

• 

The panel is correctly hooked. 

• 

The 9-pole connection is well inserted (

Picture 9b

).

• 

The red reset key above the electric system box is 
pressed. 

• 

The wires in the 9-pole connection are well inserted into 
the connector. (During connection, exerting an 
overpressure may cause the contacts to bend). 

The hood has low efficiency 

Make sure that: 
• 

The motor speed selected is sufficient for the quantity of 
fumes present 

• 

The kitchen is aired enough to allow an air intake and the 
charcoal filter is not worn out (filter version hood). 

• 

The air outlet pipe is not clogged. 

• 

The suction unit non-return valves can rotate freely. 

The hood stops during operation 

Make sure that: 
• 

There is no current blackout 

• 

The differential magnetothermal switch (automatic circuit 
breaker) has not been released. 

Maintenance 

Cleaning

Clean using 

ONLY

 the cloth dampened with neutral liquid 

detergent. 

DO NOT CLEAN WITH TOOLS OR 

INSTRUMENTS

. Do not use abrasive products. 

DO NOT USE 

ALCOHOL!

Grease filter 

Traps cooking grease particles. 

This must be cleaned once a month (or when the filter 
saturation indication system – if envisaged on the model in 
possession – indicates this necessity)  using non aggressive 
detergents, either by hand or in the dishwasher, which must 
be set to a low temperature and a short cycle. 
When washed in a dishwasher, the grease filter may discolour 
slightly, but this does not affect its filtering capacity. 
When inserting and removing grease filters and charcoal 
filters, please make sure that the extractable unit of the hood 
is in open position .In order to do this,pull the 

OFF

 (

T5

)key. 

Then remove the front panel ,by pulling on the upper part of 
each side at the same time (

Fig.13

).

The panel turns forward ,so that grease filters can be inserted 
(

Fig.14

).

Charcoal filter (filter version only) 

It absorbs unpleasant odours caused by cooking. 

The saturation of the 

charcoal filter

 occurs after more or less 

prolonged use, depending on the type of cooking and the 
regularity of cleaning of the grease filter. 
In any case it is necessary to replace the cartridge at least 
every four months. 
The charcoal filter may NOT be washed or regenerated. 
After removing the grease filter, it is possible to insert the 
charcoal filters (

Fig. 15

) (

not supplied

).

Summary of Contents for HH-TVG90A

Page 1: ...ign Center Office 128 Thዙy Khuê P Thዙy Khuê Quኼn Tây Hዏ Hà Nዒi Tel 84 4 38 500 400 Fax 84 4 38 500 401 Email hanoi hafele com vn Häfele Da Nang Design Center Office 248 Nguyወ Quኼn Thanh Khêǡ Ǥ 0 ዀng Tel 84 511 3584 966 Fax 84 511 3584 977 Email danang sales hafele com vn Häfele Nha Trang Office 133 Thái Nguyên ዛዕ ዛዔc Tân TP Nha Trang Tel 84 58 3560 988 Fax 84 58 3560 989 Email nhatrang hafele com ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ...e hazards involved Children shall not be allowed to tamper with the controls or play with the appliance Cleaning and user maintenance shall not be made by children without supervision The premises where the appliance is installed must be sufficiently ventilated when the kitchen hood is used together with other gas combustion devices or other fuels The hood must be regularly cleaned on both the ins...

Page 8: ...ing and kept it running for few minutes after cooking is finished Increase the speed only in case of large amount of smoke and vapour and use boost speed s only in extreme situations Replace the charcoal filter s when necessary to maintain a good odour reduction efficiency Clean the grease filter s when necessary to maintain a good grease filter efficiency Use the maximum diameter of the ducting s...

Page 9: ...sible for capacity or noise problems and no warranty will be granted Before making the hole make sure that the inside of the cabinet near the hood housing area does not have the structure of the cabinet or other particulars which may cause problems for the proper installation Make sure that the overall dimensions of the hood and the hob ae compatible with the cabinet and therefore the installation...

Page 10: ...ly for remote GME 88 Suction speed 3 power is timed for 7 minutes after which the hood will automatically switch to suction speed 2 power Suction speed 4 power is timed for 6 minutes after which the hood will automatically switch to suction speed 2 power Note If the panel is closed hood is off key T3 activates the opening of the suction panel first and then sets the hood to the suction speed power...

Page 11: ...ch the key turning it clockwise to open the panel and activate the hood at speed 1 T4 Hob light ON OFF key Press for more than 3 seconds to switch the hob light on or off Note If the panel is already open the light will switch on even by applying a short pressure Note If you want to close the panel as well it s enough to apply a light pressure for the second time T7 Filter clogging indicator reset...

Page 12: ...logged The suction unit non return valves can rotate freely The hood stops during operation Make sure that There is no current blackout The differential magnetothermal switch automatic circuit breaker has not been released Maintenance Cleaning Clean using ONLY the cloth dampened with neutral liquid detergent DO NOT CLEAN WITH TOOLS OR INSTRUMENTS Do not use abrasive products DO NOT USE ALCOHOL Gre...

Page 13: ...ft the trolley 2 Disconnect from power supply this operation can be carried out by disconnecting the plug if accessible or open the switch if envisaged during installation or press the red button in the control box Fig 10c 3 Remove the screws which fix the upper front as shown in Fig 16 4 Lift the upper front Fig 17 5 Remove the damaged neon Fig 18 and replace it with one having the same character...

Page 14: ......

Page 15: ...LIB0007078F Ed 03 16 ...

Reviews: