background image

2

 ® Copyright 2010 by   Schulte-Schlagbaum AG
 

 

 

Nevigeser Straße 100-110

 

 

 

D-42553 Velbert

 

 

 

Phone: +49 2051 2086-0

 

 

 

http:/www.sag-schlagbaum.com

Document number:    6-703-2 34R1.0

 

• This manual replaces all previous versions.

 

• The details in this manual are subject to change without prior notification.

 

• The compilation of the information in this manual is carried out to the best of our knowledge. 

 

   Schulte-Schlagbaum AG does not assume any liability for the correctness and completeness of the  

 

   details in this manual. In particular, Schulte-Schlagbaum AG cannot be held liable for consequential  

 

   damages on account of faulty or incomplete details.  

 

• Relaying and duplication of this document and the exploitation and communication of its contents

 

   are not permitted unless expressly allowed. Violations shall obligate to provide compensation for    

 

   damages. All rights reserved in the event of patent grant or registration of a utility model or design.

Means of depiction

The following means of depiction are used in this manual: 

 

Notice

  

 

Please observe this important information.

 

Handling instructions

 

 

These mark a work step during user input.

SAFE-O-TRONIC®

 is a registered trademark of Schulte-Schlagbaum AG.

Safety and warning notes 

  

   

Please read before initial operation

.

 

• This manual describes the initial operation and operation of a SAFE-O-TRONIC® LS 100.

 

• The equipment must only be used for the purpose intended by the manufacturer.

 

• Please keep the instruction manual in an easily accessible place. 

 

• Unauthorized amendments and the use of spare parts and auxiliary devices that are not sold or    

 

   recommended by the manufacturer of the equipment can cause fires, electric shocks and injuries.

 

   The manufacturer will not be liable.

 

• Repair work must only be carried out by the manufacturer.

 

• The warranty provisions of the manufacturer as amended on the date of purchase shall apply to the  

 

   equipment. Liability will not be assumed for unsuitable and automatic compilation of parameters for a  

 

   device or unsuitable application of a device.  

 

• The operating company shall bear the responsibility that the device is installed and connected 

 

   according to recognized technical rules in the country of installation as well as other valid regulations.  

Notes on this manual

Summary of Contents for SAFE-O-TRONIC LS 100

Page 1: ...AFE O TRONIC access Item No 231 98 000 001 002 003 MountingInstructions Dimensions in mm Inches are approximate Electronic Identification and Locking System SAFE O TRONIC LS Cabinet Lock Manual LS 100...

Page 2: ...ease observe this important information Handling instructions These mark a work step during user input SAFE O TRONIC is a registered trademark of Schulte Schlagbaum AG Safety and warning notes Please...

Page 3: ...d 9 UserCode 9 MasterCode1 9 MasterCode2 9 Codeoverview 9 Operation 10 Function control 10 Initial operation 11 Programming MasterCode2 11 Locking and opening using MasterCode2 12 Locking and opening...

Page 4: ...Exchangeable plate Rotary knob OK key Finish of Code entry Abort key Code entries or programming operations can be rejected by pressing the abort key Keys 1 2 3 4 5 6 7 8 9 0 Number keys for Code entr...

Page 5: ...am A cropped or hook shaped locking lever can also be used depending on the properties and condition of the cabinet 5 Fastening bolt for locking lever 6 Bushing for fastening the lock to the door for...

Page 6: ...o the two holes 19 1 mm 16 mm and 7 mm 2 Fasten the lock 1 using the nut 2 3 Screw on the lock 1 using the screw 8 and the bushing 6 or 7 depending on the thickness of the door 4 Fasten the grommet 3...

Page 7: ...g 2 Grommet that is attached to the lock on the inside of the door The opening marked L points downwards 3 Rear side of the lock to which the grommet is attached If the lock is installed in a position...

Page 8: ...the plate e g for numbers logo etc After inserting a small screwdriver into the center of the plate the old plate is levered out of the lock A new plate can then be snapped in Notice The old plate is...

Page 9: ...only aware of the MasterCode1 they are protected against suspicion in cases of hidden thefts It means if there is a theft and the compartment has been locked again the employees cannot come into quest...

Page 10: ...sabled for one minute as protection against manipulation The lock is blocked after 100 incorrect entries Blocking can only be released with MasterCode2 All locks in the SAFE O TRONIC LS 100 series are...

Page 11: ...grammed MasterCode2 Programming MasterCode2 Press the OK and abort keys simultaneously and Enter new MasterCode2 Notice 3 5 1 9 7 is only an example code Press the OK key Enter new MasterCode2 one mor...

Page 12: ...rCode2 Notice 3 5 1 9 7 is only an example code Then press the OK key Turn the knob Locking and opening using the UserCode The user has the possibility to enter a random 4 digit UserCode and lock and...

Page 13: ...ode2 Notice 3 5 1 9 7 is only an example code Press the OK key Press 2 2 for MasterCode2 Press the OK key Enter new MasterCode2 Notice 4 8 2 7 3 is only an example code Press the OK key Enter new Mast...

Page 14: ...ot permitted Press the OK and abort keys simultaneously and Enter active MasterCode2 Notice 3 5 1 9 7 is only an example code Press the OK key Press 1 1 for MasterCode1 Press the OK key Enter new Mast...

Page 15: ...at is fitted with a SAFE O TRONIC LS 100 is opened using MasterCode1 it stays blocked for the entry of a UserCode The SAFE O TRONIC LS 100 then has to be released again using MasterCode2 Enter active...

Page 16: ...ror the rotary knob was not operated within the released period Alternate Waiting for rotary knob to be operated 1 second Lock has been locked programming successful 2 seconds Lock has been unlocked 1...

Page 17: ...tal regulations Battery monitoring battery alarm Automatic battery monitoring on the SAFE O TRONIC LS 100 ensures that a SAFE O TRONIC LS 100 with inadequate battery voltage can no longer be operated...

Page 18: ...0 C to 65 C 14 F to 149 F Storage 25 C to 65 C 13 F to 149 F Relative humidity 10 90 non condensing Protection class according To DIN EN 60529 IP 43 Weight approx 300 g 10 1 2 oz Housing dimensions in...

Page 19: ...e NC 27263 1 800 423 3531 www hafele com Further Functions Notice Depending on the printer there can be dimensional deviations when printing this drilling template Therefore please re measure the dril...